KV Nano Series Base Unit PLC Keyence
Kitoma Indonesia - KV Nano Series Base Unit PLC Keyence
High Speed & High Performance All-in-one PLC
- High speed & High Performance
- High Reliability Design
- Seamless
KV Nano Base Unit Lineup
14 point terminal block type
|
40 point terminal block type
|
![]() |
![]() |
24 point terminal block type
|
60 point terminal block type
|
![]() |
![]() |
14 point terminal block type
- KV-N14AR : AC Power supply/relay output
- KV-N14AT(P) : AC Power supply/transistor output
- KV-N14DR : DC Power supply/relay output
- KV-N14DT(P) : DC Power supply/transistor output
24 point terminal block type
- KV-N24AR : AC Power supply/relay output
- KV-N24AT(P) : AC Power supply/transistor output
- KV-N24DR : DC Power supply/relay output
- KV-N24DT(P) : DC Power supply/transistor output
40 point terminal block type
- KV-N40AR : AC Power supply/relay output
- KV-N40AT(P) : AC Power supply/transistor output
- KV-N40DR : DC Power supply/relay output
- KV-N40DT(P) : DC Power supply/transistor output
60 point terminal block type
- KV-N60AR : AC Power supply/relay output
- KV-N60AT(P) : AC Power supply/transistor output
Features
- High Speed
- High Performance Built-in Positioning
- Utilising the High Speed
- Modbus Master/Slave Function
- Serial PLC Link Function
- LCD Display Unit (Acces Window)
- Analogue unit
- High Reliability
- Enhanced Password/Security Function
Table of functions by base unit points
KV-N14xx *1 | KV-N24xx | KV-N40xx | KV-N60xx | KV-NC32T | |
AC power supply type | ![]() |
![]() |
![]() |
![]() |
— |
---|---|---|---|---|---|
DC power supply type | ![]() |
![]() |
![]() |
— | ![]() |
Programme capacity *2 | 8k steps | 8k steps | 16k steps | 16k steps | 32k steps |
Built-in I/O | In: 8 points Out: 6 points |
In: 14 points Out: 10 points |
In: 24 points Out: 16 points |
In: 36 points Out: 24 points |
In: 16 points Out: 16 points |
Max. number of I/O points | 128 points | 256 points | 256 points | 256 points | 256 points |
Max. number of expansion units connectable | 3 units | 8 units | 8 units | 8 units | 8 units |
Number of positioning axes *3 | 2 axes, 100 kHz Open collector |
2 axes, 100 kHz Open collector |
3 axes, 100 kHz Open collector |
4 axes, 100 kHz Open collector |
3 axes, 100 kHz Open collector |
High-speed counter function | 100 kHz max, 2 channels |
100 kHz max, 2 channels |
100 kHz max, 3 channels |
100 kHz max, 4 channels |
100 kHz max, 3 channels |
Interrupt input function | 4 points | 4 points | 4 points | 4 points | 4 points |
Base unit CPU built-in serial port |
1 port (general communication possible) |
1 port (general communication possible) |
1 port (general communication possible) |
1 port (general communication possible) |
1 port (general communication possible) |
Extension cassette serial port | 1 port max. | 1 port max. | 2 ports max. | 2 ports max. | — |
USB port | 1 port | 1 port | 1 port | 1 port | 1 port |
Analogue unit connection | ![]() (3 units max.) |
![]() (8 units max.) |
![]() (8 units max.) |
![]() (8 units max.) |
![]() (8 units max.) |
Serial PLC Link function | ![]() |
![]() |
![]() |
![]() |
![]() |
Modbus master/slave function | ![]() (RTU mode supported) |
![]() (RTU mode supported) |
![]() (RTU mode supported) |
![]() (RTU mode supported) |
![]() (RTU mode supported) |
SD card slot | — | — | — | — | ![]() |
Logging function | — | — | — | — | ![]() |
Serial adapter | — | — | — | — | ![]() (1 unit max.) |
List of Hardware
Item name/category | Model | Remark | |
---|---|---|---|
Base unit | 14-point AC power supply type |
KV-N14AR* | Input 8 points/output 6 points, relay output, programme capacity 8k steps |
KV-N14AT(P)* | Input 8 points/output 6 points, transistor (sink/source) output, programme capacity 8k steps |
||
14-point DC power supply type |
KV-N14DR | Input 8 points/output 6 points, relay output, program capacity 8k steps |
|
KV-N14DT(P)* | Input 8 points/output 6 points, transistor (sink/source) output, programme capacity 8k steps |
||
24-point AC power supply type |
KV-N24AR | Input 14 points/output 10 points, relay output, programme capacity 8k steps |
|
KV-N24AT(P) | Input 14 points/output 10 points, transistor (sink/source) output, programme capacity 8k steps |
||
24-point DC power supply type |
KV-N24DR | Input 14 points/output 10 points, relay output, programme capacity 8k steps |
|
KV-N24DT(P) | Input 14 points/output 10 points, transistor (sink/source) output, programme capacity 8k steps |
||
40-point AC power supply type |
KV-N40AR | Input 24 points/output 16 points, relay output, programme capacity 16k steps |
|
KV-N40AT(P) | Input 24 points/output 16 points, transistor (sink/source) output, programme capacity 16k steps |
||
40-point DC power supply type |
KV-N40DR | Input 24 points/output 16 points, relay output, programme capacity 16k steps |
|
KV-N40DT(P) | Input 24 points/output 16 points, transistor (sink/source) output, programme capacity 16k steps |
||
60-point AC power supply type |
KV-N60AR | Input 36 points/output 24 points, relay output, programme capacity 16k steps |
|
KV-N60AT(P) | Input 36 points/output 24 points, transistor (sink/source) output, programme capacity 16k steps |
||
Expansion unit | Input | KV-N8EX | 8 points, 5/24 VDC switchable, screw terminal block |
KV-N16EX | 16 points, 5/24 VDC switchable, screw terminal block | ||
Output | KV-N8ER | 8 points, relay output, screw terminal block | |
KV-N8ET(P) | 8 points, transistor (sink/source) output, screw terminal block | ||
KV-N16ER | 16 points, relay output, screw terminal block | ||
KV-N16ET(P) | 16 points, transistor (sink/source) output, screw terminal block | ||
Input/output | KV-N8EXR | Input 8 points/output 8 points, relay output, screw terminal block |
|
KV-N8EXT | Input 8 points/output 8 points, transistor (sink) output, screw terminal block |
||
A/D-D/A conversion | KV-N3AM | Voltage/current input 2 channels + Voltage/current output 1 channel | |
Extension cassette | Serial communication | KV-N10L | 1 port (RS-232C x 1 channel) |
KV-N11L | 1 port (RS-422A/RS-485 (4-wire)/RS-485 (2-wire) x 1 channel), European terminal block |
||
Access window | KV-N1AW | LCD display unit, memory cassette function | |
Option | Extension cable | OP-87581 | Cable length 1 m, width 2 cm |
USB cable | OP-35331 | Cable length 3 m |
General specifications - Base unit
Power supply type | AC power supply type | DC power supply type | ||||
---|---|---|---|---|---|---|
Model | KV-N14Ax/N24Ax/N40Ax/N60Ax | KV-N14Dx/N24Dx/N40Dx | ||||
Supply voltage | 100 to 240 VAC (+10%/-15%) | 24 VDC (+10%/-15%) | ||||
Output power supply voltage | 24 VDC (±10%; output capacity: 0.6 A) | − | ||||
Internal current consumption | KV-N14AR: 76 VA, KV-N14AT(P): 75 VA, KV-N24AR: 79 VA, KV-N24AT(P): 76 VA, KV-N40AR: 86 VA, KV-N40AT(P): 82 VA, KV-N60AR: 91 VA, KV-N60AT(P): 85 VA |
KV-N14DR: 160 mA, KV-N14DT(P): 150 mA, KV-N24DR: 190 mA, KV-N24DT(P): 160 mA, KV-N40DR: 280 mA, KV-N40DT(P): 250 mA |
||||
Operating ambient temperature | 0 to 55°C (no freezing) 1., 2. | |||||
Storage temperature | −25 to +75°C | |||||
Operating ambient humidity | 5 to 95% RH (no condensation) 1. | |||||
Withstand voltage | 1500 VAC for 1 minute, between power supply terminal and I/O terminals and between all external terminals and case | |||||
Noise immunity | 1500 V peak-to-peak or more, pulse width 1 μs, 50 ns (by noise simulator), IEC standard compliant (IEC61000-4-2/3/4/6) | |||||
Vibration resistance 3. | Conforms toJIS B 3502 andIEC61131-2 | Intermittent vibration | Number of scans | |||
Frequency | Acceleration | Amplitude | 10 times (100 minutes) in each of the X, Y, and Z directions |
|||
5 to 9 Hz | − | 3.5 mm | ||||
9 to 150 Hz | 9.8 m/s2 | − | ||||
Continuous vibration | ||||||
Frequency | Acceleration | Amplitude | ||||
5 to 9 Hz | − | 1.75 mm | ||||
9 to 150 Hz | 4.9 m/s2 | − | ||||
Shock resistance | Acceleration: 150 m/s2, application time: 11 ms, two times in each of the X, Y, and Z directions | |||||
Insulation resistance | 50 MΩ or more (500 VDC megger used to perform measurements between power terminal and input terminals, and between all external terminals and case) |
|||||
Operating environment | As little dust and corrosive gases as possible | |||||
Operating altitude | 2000 m or less | |||||
Overvoltage category | AC: II, DC: I | |||||
Pollution degree | 2 | |||||
Weight | KV-N14AR: 430 g, KV-N14AT(P): 420 g, KV-N24AR: 500 g, KV-N24AT(P): 470 g, KV-N40AR: 660 g, KV-N40AT(P): 620 g, KV-N60AR: 820 g, KV-N60AT(P): 750 g |
KV-N14DR: 350 g, KV-N14DT(P): 330 g, KV-N24DR: 420 g, KV-N24DT(P): 390 g, KV-N40DR: 580 g, KV-N40DT(P): 530 g |
Untuk informasi lebih lanjut silakan hubungi bagian Marketing kami, kami senang untuk membantu :
Hubungi | : Sales & Marketing |
Alamat |
: Simprug Plaza |
Jl. Simprug Raya Blok B.2 No.5 Cikarang Baru Jababeka II - Bekasi 17530 |
|
Telepon |
: 021 2851 8058 | 021 2851 8059 | 021 3725 0521 | 021 4448 9918 |
Mobile | : 0821 2570 0690 | 0858 9027 2127 | 0877 8228 6338 |
Fax | : 021 2851 8058 |
: sales@kitomaindonesia.com | emma@kitomaindonesia.com | kitoma_kitoma@yahoo.co.id |