Mail Us at : sales@kitomaindonesia.com | Call Us 021 2851 8059

Switch Mode Power Supply S8VM

 

 

Kitoma Indonesia - Switch Mode Power Supply S8VM
(15/30/50/100/150/300/600/1,500-W Models)


Power Supply Featuring OMRON's Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizin

 

Features

New undervoltage alarm function assists in determining causes of errors (S8VM-[][][]24A[]/P[] only).

Power failure alarm function provides notification of output voltage errors (300-, 600-, and 1,500-W models only).

Broad range of possibilities with 8 capacities and 29 models to choose from.

RoHS-compliant

New, attentive design prevents screws from falling out of terminal block (except for output terminals of 300-, 600-, and 1,500-W models).

Finger protection prevents electric shock.

DIN Rail mounting.

Safety standards: UL508/60950-1/1604, CSA C22.2 No. 14/No. 60950-1/No. 213, EN50178, EN60950-1 (The 300-, 600-, and 1,500-W models will not conform to safety standards if the customer replaces the fan.)

Conforms to SEMI F47-0200 (when 200-V input is used).

Harmonic current emissions: Conforms to EN61000-3-2 (except for 15- and 30-W models).

 

Specifications


Power rating 15 W 30 W 50 W 100 W 150 W
Efficiency 5-V models 75% min. 75% min. 80% min. 81% min. 81% min.
12-V models 78% min. 79% min. 79% min. 81% min. 81% min.
15-V models 78% min. 79% min. 79% min. 81% min. 81% min.
24-V models 80% min. 81% min. 80% min. 82% min. 83% min.
Input Voltage (See note 1.) 100 to 240 VAC (85 to 264 VAC)
Frequency (See note 1.) 50/60 Hz (47 to 63 Hz)
Current 100-V input 0.5 A max. 0.9 A max. 0.8 A max. 1.4 A max. 2.0 A max.
200-V input 0.25 A max. 0.45 A max. 0.4 A max. 0.7 A max. 1.0 A max.
Power factor 100-V input --- 0.98 min.
200-V input --- 0.94 min.
Harmonic current emissions --- Conforms to EN 61000-3-2
Leakage
current
100-V input 0.4 mA max. (at rated output)
200-V input 0.75 mA max. (at rated output)
Inrush current
(See note 2.)
100-V input 17.5 A max. (for cold start at 25 ° C)
200-V input 35 A max. (for cold start at 25 ° C)
Output Voltage adjustment range
(See note 3.)
-20% to 20% (with V. ADJ) (S8VM-[][][]24A[]/P[]: -10% to 20%)
Ripple 3.2% (p-p) max. (5 V),
1.5% (p-p) max. (12 V),
1.2% (p-p) max. (15 V),
1.0% (p-p) max. (24 V),
(at rated input/output voltage)
3.2% (p-p) max. (5 V),
1.5% (p-p) max. (12 V),
1.2% (p-p) max. (15 V),
0.75% (p-p) max. (24 V),
(at rated input/output voltage)
Input variation influence 0.4% max. (at 85 to 264 VAC input, 100%)
Load variation influence
(rated input voltage)
0.8% max. (with rated input, 0 to 100% load)
Temperature variation
influence
0.02%/°C max.
Startup time (See note 2.) 1,100 ms max. (at rated input/output
voltage)
800 ms max. (at rated input/output voltage)
Hold time (See note 2.) 20 ms typ. (15 ms min.) (at rated input/output voltage)
Additional
functions
Overload protection
(See note 2.)
105% to 160% of rated load current,
voltage drop, intermittent, automatic
reset
105% to 160% of rated load current,
voltage drop (12 V, 15 V, and 24 V),
voltage drop, intermittent (5 V), automatic reset
Overvoltage protection
(See note 2.)
Yes (See note 4.)
Undervoltage alarm indication Yes (color: Yellow (DC LOW1), red (DC LOW2)) (S8VM-[][][]24A[]/P[] only)
Undervoltage alarm output No Yes (S8VM-[][][]24A[]/P[] only)
(Transistor output), 30 VDC max., 50 mA max.
(See note 8.)
Series operation Yes for up to 2 Power Supplies (with external diode)
Parallel operation No
Remote sensing function No Yes
Other Ambient operating temperature Refer to the derating curve in See Engineering Data on Data Sheet (15-W, 30-W, 50-W,
100-W, 150-W Models). (with no icing or condensation) (See note 2.)
Storage temperature -25 to 65°C
Ambient operating humidity 30% to 85% (Storage humidity: 25% to 90%)
Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE/FG terminals; detection current: 20 mA)
500 VAC for 1 min. (between all outputs and PE/FG terminals; detection current: 100 mA)
500 VAC for 1 min. (between all outputs (except the detection output terminals) and detection
output terminals; detection current: 20 mA) (S8VM-[][][]24A[]/P[] only)
Insulation resistance 100 MΩ min. (between all outputs and all inputs, PE/FG terminals) at 500 VDC
Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 hours each in X, Y, and Z directions
Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions
Output indicator Yes (color: Green)
EMI Conducted
Emission
Conforms to EN61204-3 EN55011 Class B and based on FCC Class B (See note 5.)
Radiated
Emission
Conforms to EN61204-3 EN55011 Class B (See note 6.)
EMS Conforms to EN61204-3 High severity levels
Approved
standards
UL UL508 (Listing), UL60950-1, UL1604 (Listing; Class I/Division 2, Group A, B, C, D Hazardous
Locations) (See note 9.)
cUL CSA C22.2 No.14, No. 213 (Class I/Division 2, Group A, B, D, D Hazardous Locations)
cUR CSA No. 60950-1
EN/TÜV EN50178, EN60950-1
SELV (EN60950-1)
According to VDE0160/P100
SEMI SEMI F47-0200 (200 VAC input)
Weight (See note 7.) 180 g max. 220 g max. 290 g max. 460 g max. 530 g max.

Note:

  1. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning.
  2. Refer to Engineering Data (15-W, 30-W, 50-W, 100-W, 150-W Models) on Data Sheet for details.
  3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +20% of the voltage adjustment range. If the adjuster is turned too far, it may activate the overvoltage protection function and interrupt the output. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged.
  4. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON.
  5. Conducted emissions: The noise value is affected by factors such as the wiring method. The Power Supply conforms to Class B when the aluminum plate is laid under the Power Supply. For 15-W models, insert a clamp filter (ZCAT2436-1330 by TDK: 50 Ω min. [50 to 500 MHz], or the equivalent) in the output wire to reduce noise.
  6. Radiated emissions: The noise value is affected by factors such as the wiring method. The Power Supply conforms to Class B when the aluminum plate is laid under the Power Supply. For 150-W models, insert a clamp filter (ZCAT2017-0930 by TDK: 35 Ω min. [50 to 500 MHz], or the equivalent) in the input wire to reduce noise.
  7. The weight indicated is for bottom mounting, open-frame models.
  8. A[]: Sinking type (NPN), P[]: Sourcing type (PNP)
  9. With the S8VM-15024[][], the output current for UL1604 certification is 6.3 A.

 

Power rating 300 W 600 W 1,500 W
Efficiency 5-V models 77% min. 77% min. ---
12-V models 78% min. 79% min. ---
15-V models 79% min. 80% min. ---
24-V models 81% min. 81% min. 82% min.
Input Voltage (See note 1.) 100 to 240 VAC (85 to 264 VAC) 100 to 240 VAC (85 to 265 VAC)
Frequency (See note 1.) 50/60 Hz (47 to 63 Hz)
Current 100-V input 4.0 A max. (5 V)
4.3 A max. (12 V, 15 V, and
24 V)
8.0 A max. (5 V)
8.3 A max. (12 V, 15 V, and
24 V)
20.0 A max.
200-V input 2.0 A max. (5 V)
2.2 A max. (12 V, 15 V, and
24 V)
4.0 A max. (5 V)
4.2 A max. (12 V, 15 V, and
24 V)
11.0 A max.
Power factor 100-V input 0.98 min. 0.97 min.
200-V input 0.94 min. 0.93 min.
Harmonic current emissions Conforms to EN61000-3-2
Leakage
current
100-V input 0.4 mA max. 1.5 mA max.
200-V input 0.75 mA max. 1.5 mA max.
Inrush current
(See note 2.)
100-V input 20 A max. (for cold start at 25 ° C)
200-V input 40 A max. (for cold start at 25 ° C)
Output Voltage adjustment range
(See note 3.)
-20% to 20% (with V. ADJ)
Ripple 3.8% (p-p) max. (5 V), 2.0% (p-p) max. (12 V), 2.0% (p-p)
max. (15 V), 1.25% (p-p) max. (24 V), (at rated input/output
voltage)
1.25% (p-p) max. (See note 7.),
(at rated input/output voltage)
Input variation influence 0.4% max. (at 85 to 264 VAC input, 100%)
Load variation influence
(rated input voltage)
0.6% max. (with rated input, 0 to 100% load)
Temperature variation
influence
0.02%/°C max.
Startup time (See note 2.) 1,000 ms max. (at rated input/output voltage)
Hold time (See note 2.) 20 ms typ. (15 ms min.) (at rated input/output voltage)
Additional
functions
Overload protection
(See note 2.)
105% to 160% of rated load current (5 V, 12 V, and 15 V),
120% to 160% of rated load current (S8VM-30024C), 115%
to 160% of rated load current (S8VM-60024C), voltage
drop (12 V, 15 V, and 24 V), voltage drop, intermittent
(5 V), automatic reset
105% to 160% of rated load
current (100 VAC),
155% to 200% of rated load
current (200 VAC),
voltage drop, automatic reset
(Turns OFF when continuous
for 5 s min.) (See note 4.)
Overvoltage protection
(See note 2.)
Yes (See note 4.)
Overheat protection
(See note 2.)
Yes (See note 4.)
Undervoltage alarm indication No
Undervoltage alarm output No
Power failure alarm indication Yes (color: Red)
Power failure alarm output Yes (Transistor output), 30 VDC max., 50 mA max.
Series operation Yes for up to 2 Power Supplies (with external diode)
Parallel operation Yes (Up to 2 units)
Remote sensing function Yes
Remote control function Yes
Other Ambient operating
temperature
Refer to the derating curve in See Engineering Data on Data Sheet (300-W, 600-W, 1,500-W
Models). (with no icing or condensation) (See note 2.)
Storage temperature -25 to 65°C
Ambient operating humidity 30% to 85% (Storage humidity: 25% to 90%)
Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs;
detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals;
detection current: 20 mA)
500 VAC for 1 min. (between all outputs and PE terminals;
detection current: 100 mA)
100 VAC for 1 min. (between all outputs and RC terminals;
detection current: 100 mA)
500 VAC for 1 min. (between all outputs and PF terminals;
detection current: 20 mA)
3.0 kVAC for 1 min. (between
all inputs and outputs;
detection current: 20 mA)
2.0 kVAC for 1 min. (between
all inputs and FG terminals;
detection current: 20 mA)
500 VAC for 1 min. (between
all outputs and FG terminals;
detection current: 300 mA)
100 VAC for 1 min. (between
all outputs and RC terminals;
detection current: 100 mA)
500 VAC for 1 min. (between
all outputs and PF terminals;
detection current: 20 mA)
Insulation resistance 100 MΩ min. (between all outputs and all inputs, PE terminals)
at 500 VDC
100 MΩ min. (between all
outputs and all inputs, FG
terminals) at 500 VDC
Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 hours each in X,
Y, and Z directions
10 to 55 Hz, 0.15-mm single
amplitude for 2 hours each in
X, Y, and Z directions
Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions
Output indicator Yes (color: Green)
EMI Conducted
Emission
Conforms to EN61204-3 EN55011 Class B and based on FCC
Class B (See note 5.)
Conforms to EN61204-3
EN55011 Class A and based
on FCC Class A (See note 6.)
Radiated
Emission
Conforms to EN61204-3 EN55011 Class B (See note 5.) Conforms to EN61204-3
EN55011 Class A (See note 6.)
EMS Conforms to EN61204-3 High severity levels
Approved
standards
(See note 8.)
UL UL508 (Recognition) (5 V, 12 V, and 15 V) UL508 (Listing) (24
V), UL60950-1
UL1604 (Listing; Class I/Division 2, Group A, B, C, D Hazardous
Locations) (24 V)
UL508, UL60950-1
cUR CSA C22.2 No.14, No. 213 (Class I/Division 2, Group A, B C, D
Hazardous Locations) (24 V)
 
cUR CSA No. 60950-1 CSA C22.2 No.14,
CSA No. 60950-1
EN/TÜV EN50178, EN60950-1
SELVE (EN60950-1)
EN50178, EN60950-1
SELVE (EN60950-1)
SEMI SEMI F47-0200 (200-VAC input)
Weight 1,100 g max. 1,700 g max. 3,800 g max.

 

 

Untuk informasi lebih lanjut silakan hubungi bagian Marketing kami, kami senang untuk membantu :

 

Hubungi : Sales & Marketing
Alamat

: Simprug Plaza

 

  Jl. Simprug Raya Blok B.2 No.5 Cikarang Baru Jababeka II - Bekasi 17530

Telepon
: 021 2851 8058  |  021 2851 8059  |  021 3725 0521  |  021 4448 9918
Mobile : 0821 2570 0690  |  0858 9027 2127  |  0877 8228 6338
Fax : 021 2851 8058
Email : sales@kitomaindonesia.com  |  marketing@kitomaindonesia.com  |  kitoma_kitoma@yahoo.co.id