Mail Us at : sales@kitomaindonesia.com | Call Us 021 2851 8059

PLC LG/LS Glofa GM6-PAFA

 

 

Kitoma Indonesia - PLC LG/LS Glofa GM6-PAFA

 

PLC LG GM6-PAFA K3P-07AS G6I-D22A X3 G6Q-RY2A X3

 

GM6 are module-type PLC that consist of various modules including basic module(CPU, Power, I/O), communication module and special module. And through various modules, user can configure the optimum system for industry environment.
 

 

Features

  • High performance features with compact size
  • High-speed processing using dedicated CPU
  • Designed by international standard language (IEC61131-3): IL, LD, SFC
  • Max. I/O points: 384 points

 

Specification

 

Item Specifications Remark
GM6-CPUA GM6-CPUB GM6-CPUC
Operation method Cyclic execution of stored program, Time-driven operation, Internal task operation  
I/O control method Scan synchronized batch processing method (Refresh method)  
Program language LD (Ladder Diagram)
IL (Instruction List)
SFC (Sequential Function Chart)
 
Number of instructions Operator LD : 13, IL : 20  
Standard function 194  
Standard function block 12  
Special function block Each special module has its own special function block.  
Processing speed Operator 0.5㎲/instruction  
Standard function 0.5㎲/step  
Standard function block  
Programming memory capacity (Kbyte) 68Kbyte Built-in flash memory (128Kbyte)
I/O points 192 points (With 32-pt modules) 384 points (With 64-pt modules)  
Data memory Direct variable area (D/A) 2~ 8Kbyte Setting in GMWIN
Symbolic variable area (SVA) 30K- Direct variable area  
Timer No limitation
Timer range: 0.001 ~ 4294967sec(1,193 hours)
20 bytes per 1 timer in SVA
Counter No limitation
No limitation : -32768 ~ +32767
8 bytes per 1 counter in SVA
Operation mode RUN, Stop, Debug, Pause  
Data retention at power failure Set to "Retain' at data declaration  
Number of program blocks 100  
Program type Scan 100  
Time-driven 8 8 in total
External interrupt 8
Internal 8
Initialization 1 (_INIT)  
Self-diagnostic Watchdog timer, Memory error, I/O error, Batter error, Power supply error  
Restart mode Cold, Warm  
Base type 4/6/8/12 slot Expansion is not available.
Built-in functions - Cnet (RS-232C) - PID control
- Cnet (RS-422/485)
- RTC function
- PID control
- Cnet (RS-232C)
- HSC (50kHz)
- RTC function
 

 

 

 

Untuk informasi lebih lanjut silakan hubungi bagian Marketing kami, kami senang untuk membantu :

 

Hubungi : Sales & Marketing
Alamat

: Simprug Plaza

 

  Jl. Simprug Raya Blok B.2 No.5 Cikarang Baru Jababeka II - Bekasi 17530

Telepon
: 021 2851 8058  |  021 2851 8059  |  021 3725 0521  |  021 4448 9918
Mobile : 0821 2570 0690  |  0858 9027 2127  |  0877 8228 6338
Fax : 021 2851 8058
Email : sales@kitomaindonesia.com  |  emma@kitomaindonesia.com  |  kitoma_kitoma@yahoo.co.id