Inverter Fuji Electric FRENIC-Eco 3-phase 400V Series
Kitoma Indonesia - Inverter Fuji Electric FRENIC-Eco 3-phase 400V Series
Variable Torque Load Inverters for Fans and Pumps
Inverter Fuji Electric FRENIC-Eco 3 phase 400V, 0.75kW - 560kW
FRENIC-Eco 3-phase 400V Standard Type Models
- FRN0.75F1S-4A (0.75 kW)
- FRN1.5F1S-4A (1.5 kW)
- FRN2.2F1S-4A (2.2 kW)
- FRN3.7F1S-4A (3.7 kW
- FRN5.5F1S-4A (5.5 kW)
- FRN7.5F1S-4A (7.5 kW)
- FRN11F1S-4A (11 kW)
- FRN15F1S-4A (15 kW)
- FRN18.5F1S-4A (18.5 kW)
- FRN22F1S-4A (22 KW)
- FRN30F1S-4A (30 kW)
- FRN37F1S-4A (37 kW)
- FRN45F1S-4A (45 kW)
- FRN55F1S-4A (55 kW)
- FRN75F1S-4A (75 kW)
- FRN90F1S-4A (90 kW)
- FRN110F1S-4A (110 kW)
- FRN132F1S-4A (132 kW)
- FRN160F1S-4A (160 kW)
- FRN200F1S-4A (200 kW)
- FRN220F1S-4A (220 kW)
- FRN280F1S-4A (280 kW)
- FRN315F1S-4A (315 kW)
- FRN355F1S-4A (355 kW)
- FRN400F1S-4A (400 kW)
- FRN450F1S-4A (450 kW)
- FRN500F1S-4A (500 kW)
- FRN560F1S-4A (560 kW)
FRENIC-Eco 3-phase 400V Built-in DC reactor series
- FRN0.75F1H-4A (0.75 kW)
- FRN1.5F1H-4A (1.5 kW)
- FRN2.2F1H-4A (2.2 kW)
- FRN3.7F1H-4A (3.7 kW
- FRN5.5F1H-4A (5.5 kW)
- FRN7.5F1H-4A (7.5 kW)
- FRN11F1H-4A (11 kW)
- FRN15F1H-4A (15 kW)
- FRN18.5F1H-4A (18.5 kW)
- FRN22F1H-4A (22 KW)
- FRN30F1H-4A (30 kW)
- FRN37F1H-4A (37 kW)
- FRN45F1H-4A (45 kW)
- FRN55F1H-4A (55 kW)
- FRN75F1H-4A (75 kW)
FRENIC-Eco 3-phase 400V EMC filter built-in series
- FRN0.75F1E-4A (0.75 kW)
- FRN1.5F1E-4A (1.5 kW)
- FRN2.2F1E-4A (2.2 kW)
- FRN3.7F1E-4A (3.7 kW
- FRN5.5F1E-4A (5.5 kW)
- FRN7.5F1E-4A (7.5 kW)
- FRN11F1E-4A (11 kW)
- FRN15F1E-4A (15 kW)
FRENIC-Eco 3-phase 400V Waterproof (IP54) series
- FRN0.75F1L-4A (0.75 kW)
- FRN1.5F1L-4A (1.5 kW)
- FRN2.2F1L-4A (2.2 kW)
- FRN3.7F1L-4A (3.7 kW
- FRN5.5F1L-4A (5.5 kW)
- FRN7.5F1L-4A (7.5 kW)
- FRN11F1L-4A (11 kW)
- FRN15F1L-4A (15 kW)
- FRN18.5F1L-4A (18.5 kW)
- FRN22F1L-4A (22 KW)
- FRN30F1L-4A (30 kW)
- FRN37F1L-4A (37 kW)
- FRN45F1L-4A (45 kW)
- FRN55F1L-4A (55 kW)
- FRN75F1L-4A (75 kW)
- FRN90F1L-4A (90 kW)
Specifications
3-phase 400V 0.75kW - 55kW (Standard Type)
Item | Specifications | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Type (FRN***F1S-4J) |
0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | ||
Nominal applied motor (kW) *1 | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | ||
Rated capacity (kVA) *2 | 1.9 | 2.8 | 4.1 | 6.8 | 9.5 | 12 | 17 | 22 | 28 | 33 | 44 | 54 | 64 | 77 | ||
Rated voltage (V) *3 | Three-phase, 380 to 480V (with AVR function) | |||||||||||||||
Rated current (A) *4 | 2.5 | 3.7 | 5.5 | 9 | 12.5 | 16.5 | 23 | 30 | 37 | 44 | 59 | 72 | 85 | 105 | ||
Overload capability | 120% of rated current for 1min | |||||||||||||||
Rated frequency | 50, 60Hz | |||||||||||||||
Phases, voltage, frequency |
Main power supply | Three-phase, 380 to 480V, 50/60Hz | Three-phase, 380 to 440V/50Hz | |||||||||||||
Three-phase, 380 to 480V/60Hz | ||||||||||||||||
Auxiliary control power input |
Single-phase, 380 to 480V, 50/60Hz | Single-phase, 380 to 440V/50Hz | ||||||||||||||
Single-phase, 380 to 480V/60Hz | ||||||||||||||||
Auxiliary fan power input *9 | - | *10 | ||||||||||||||
Voltage/frequency allowance | Voltage: +10 to -15% (Voltage unbalance: 2% or less) *8, Frequency: +5 to -5% | |||||||||||||||
Rated current (A) *5 | (with DCR) | 1.6 | 3 | 4.5 | 7.5 | 10.6 | 14.4 | 21.1 | 28.8 | 35.5 | 42.2 | 57.0 | 68.5 | 83.2 | 102 | |
(without DCR) | 3.1 | 5.9 | 8.2 | 13.0 | 17.3 | 23.2 | 33.0 | 43.8 | 52.3 | 60.6 | 77.9 | 94.3 | 114 | 140 | ||
Required power supply capacity (kVA) *6 | 1.2 | 2.2 | 3.1 | 5.3 | 7.4 | 10 | 15 | 20 | 25 | 30 | 40 | 48 | 58 | 71 | ||
Torque (%) *7 |
20
|
10 to 15
|
||||||||||||||
DC injection braking | Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60% | |||||||||||||||
DC reactor (DCR) | Option | |||||||||||||||
Applicable safety standards | UL508C, C22.2 No.14, EN50178:1997 (Applying) | |||||||||||||||
Enclosure (IEC60529) | UL508C, C22.2 No.14, EN50178:1997 (Applying) IP20, UL open type |
IP00, UL open type | ||||||||||||||
Cooling method | Natural cooling | Fan cooling | ||||||||||||||
Mass (kg) | 3.1 | 3.2 | 3.3 | 3.4 | 5.8 | 6.0 | 6.9 | 3.4 | 9.4 | 9.9 | 11.5 | 23 | 24 | 33 |
3-phase 400V 75kW - 560kW
Item | Specifications | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Type (FRN***F1S-4J) |
75 | 90 | 110 | 132 | 160 | 200 | 220 | 280 | 315 | 355 | 400 | 450 | 500 | 560 | ||
Nominal applied motor (kW) | 75 | 90 | 110 | 132 | 160 | 200 | 220 | 280 | 315 | 355 | 400 | 450 | 500 | 560 | ||
Rated capacity (kVA) *2 | 105 | 128 | 154 | 182 | 221 | 274 | 316 | 396 | 445 | 495 | 584 | 640 | 731 | 792 | ||
Rated voltage (V) *3 | Three-phase, 380 to 480V (with AVR function) | |||||||||||||||
Rated current (A) *4 | 139 | 168 | 203 | 240 | 290 | 360 | 415 | 520 | 585 | 650 | 740 | 840 | 960 | 1040 | ||
Overload capability | 120% of rated current for 1min | |||||||||||||||
Rated frequency | 50, 60Hz | |||||||||||||||
Phases, voltage, frequency |
Main power supply | Three-phase, 380 to 440V, 50Hz or Three-phase, 380 to 480V, 60Hz |
||||||||||||||
Auxiliary control power input | Single-phase, 380 to 480V, 50/60Hz | |||||||||||||||
Auxiliary fan power input *9 |
Single-phase, 380 to 440V/50Hz Single-phase, 380 to 480V/60Hz |
|||||||||||||||
Voltage/frequency variations | Voltage: +10 to -15% (Voltage unbalance: 2% or less) *8, Frequency: +5 to -5% | |||||||||||||||
Rated current (A) *5 | (with DCR) | 138 | 164 | 201 | 238 | 286 | 357 | 390 | 500 | 559 | 628 | 705 | 789 | 881 | 990 | |
(without DCR) | - | - | - | - | - | - | - | - | - | - | - | - | - | |||
Required power supply capacity (kVA) *6 | 96 | 114 | 140 | 165 | 199 | 248 | 271 | 347 | 388 | 435 | 489 | 547 | 611 | 686 | ||
Torque (%) *7 |
10 to 15
|
|||||||||||||||
DC injection braking | Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60% | |||||||||||||||
DC reactor (DCR) | Option | |||||||||||||||
Applicable safety standards | UL508C, C22.2 No.14, EN50178:1997 (Applying) | |||||||||||||||
Enclosure (IEC60529) | IP20, UL open type | |||||||||||||||
Cooling method | Fan cooling | |||||||||||||||
Mass (kg) | 34 | 42 | 45 | 63 | 67 | 96 | 98 | 162 | 165 | 282 | 286 | 355 | 360 | 360 |
Untuk informasi lebih lanjut silakan hubungi bagian Marketing kami, kami senang untuk membantu :
Hubungi | : Sales & Marketing |
Alamat |
: Simprug Plaza |
Jl. Simprug Raya Blok B.2 No.5 Cikarang Baru Jababeka II - Bekasi 17530 Jawa Barat - Indonesia |
|
Telepon |
: 021 2851 8059 |
Mobile | : 0857 7664 0198 (Sales & Marketing) | 0812 1165 3673 |
Fax | : 021 2851 8058 |
: sales@kitomaindonesia.com | marketing@kitomaindonesia.com | scales@kitomaindonesia.com | kitomascale@gmail.com |