Wide Model Variation

 

Basic Type
Suitable for the equipment that uses a peripheral device to suppress noise or harmonics
 

 

EMC filter built-in type
By adopting built-in filter, this type is compliant with European EMC Directives category C3 (2nd Env) 'EN61800-3-2004'.
 

 

Frenic Mega 90kW to 400kW 400V 3-phase

  • FRN90G1E-4E   (110kW 400V 3 phase)
  • FRN110G1E-4E  (132kW 400V 3 phase)
  • FRN132G1E-4E  (160kW 400V 3 phase)
  • FRN160G1E-4E  (200kW 400V 3 phase)
  • FRN200G1E-4E  (220kW 400V 3 phase)
  • FRN220G1E-4E  (250kW 400V 3 phase)
  • FRN280G1E-4E  (315kW 400V 3 phase)
  • FRN315G1E-4E  (355kW 400V 3 phase)
  • FRN355G1E-4E  (400kW 400V 3 phase)
  • FRN400G1E-4E  (450kW 400V 3 phase)

 

90kW to 400kW MD mode designed for middle duty load applications


Item
Specifications
Type (FRN□□□G1E-4E)
90
110
132
160
200
220
280
315
355
400
Nominal applied motor [kW] (*2)
110
132
160
200
250
250
315
355
400
450
Output ratings Rated capacity [kVA] (*3)
160
192
231
287
356
356
445
495
563
640
Rated voltage [V] (*4)
Three-phase 380 to 480 V (with AVR function)
Rated Current [A]
210
253
304
377
468
468
585
650
740
840
Overload capability
150% for 1 min
Input ratings Voltage, frequency
Three-phase 380 to 440 V, 50 Hz
Three-phase 380 to 480 V, 60 Hz
Voltage, frequency variations
Voltage: +10 to -15% (Interphase voltage unbalance: 2% or less) (*6), Frequency: +5 to -5%
Required capacity with DCR [kVA] (*7)
140
165
 
248
271
308
388
436
489
547
Braking Torque [%] (*8)
10 to 15%
Braking transistor
-
EMC filter
Compliant with EMC Directives, Emission and Immunity: Category C3 (2nd Env.) (EN61800-3:2004)
DC reactor (DCR)
Option (*9)
Applicable safety standards
UL508C, C22.2 No.14, EN50178:1997
Enclosure (IEC60529)
IP00, UL open type
Cooling method
Fan cooling
Weight/Mass [kg]
62
64
103
103
144
144
       

(*2) Fuji 4-pole standard motor
(*3) Rated capacity is calculated by assuming the output rated voltage as 220V for 200V series and 440V for 400V series.
(*4) Output voltage cannot exceed the power supply voltage.
(*6) Voltage unbalance[%] = (Max. voltage [V] - Min. voltage [V])/Three-phase average voltage [V]×67(See IEC61800-3.) If this value is 2 to 3 %, use an optional AC reactor (ACR).
(*7) Required when a DC reactor (DCR) is used.
(*8) Average braking torque obtained by use of a motor. (Varies with the efficiency of the motor.)
(*9) A DC reactor (DCR) is an option. However, inverters with a capacity of 75 kW or above require a DCR to be connected. Be sure to connect it to those inverters.

 

 

Untuk informasi lebih lanjut silakan hubungi bagian Marketing kami, kami senang untuk membantu :

 

Hubungi : Sales & Marketing
Alamat

: Simprug Plaza

 

  Jl. Simprug Raya Blok B.2 No.5 Cikarang Baru Jababeka II - Bekasi 17530

Telepon
: 021 2851 8059  |  021 2851 8058
Mobile : 0821 2570 0690
Fax : 021 2851 8058
Email sales@kitomaindonesia.com  |  marketing@kitomaindonesia.com  |  scales@kitomaindonesia.com  | kitomascale@gmail.com