Inverter Frenic Mega 90kW to 400kW 400V 3-phase
Kitoma Indonesia - Inverter Fuji Frenic Mega 90kW to 400kW 400V 3-phase
Inverter Frenic Mega 90kW to 400kW 400V 3-phase
Wide Model Variation
Basic Type
Suitable for the equipment that uses a peripheral device to suppress noise or harmonics
EMC filter built-in type
By adopting built-in filter, this type is compliant with European EMC Directives category C3 (2nd Env) 'EN61800-3-2004'.
Frenic Mega 90kW to 400kW 400V 3-phase
- FRN90G1E-4E (110kW 400V 3 phase)
- FRN110G1E-4E (132kW 400V 3 phase)
- FRN132G1E-4E (160kW 400V 3 phase)
- FRN160G1E-4E (200kW 400V 3 phase)
- FRN200G1E-4E (220kW 400V 3 phase)
- FRN220G1E-4E (250kW 400V 3 phase)
- FRN280G1E-4E (315kW 400V 3 phase)
- FRN315G1E-4E (355kW 400V 3 phase)
- FRN355G1E-4E (400kW 400V 3 phase)
- FRN400G1E-4E (450kW 400V 3 phase)
90kW to 400kW MD mode designed for middle duty load applications
Item
|
Specifications
|
||||||||||
Type (FRN□□□G1E-4E) |
90
|
110
|
132
|
160
|
200
|
220
|
280
|
315
|
355
|
400
|
|
Nominal applied motor [kW] (*2) |
110
|
132
|
160
|
200
|
250
|
250
|
315
|
355
|
400
|
450
|
|
Output ratings | Rated capacity [kVA] (*3) |
160
|
192
|
231
|
287
|
356
|
356
|
445
|
495
|
563
|
640
|
Rated voltage [V] (*4) |
Three-phase 380 to 480 V (with AVR function)
|
||||||||||
Rated Current [A] |
210
|
253
|
304
|
377
|
468
|
468
|
585
|
650
|
740
|
840
|
|
Overload capability |
150% for 1 min
|
||||||||||
Input ratings | Voltage, frequency |
Three-phase 380 to 440 V, 50 Hz
Three-phase 380 to 480 V, 60 Hz |
|||||||||
Voltage, frequency variations |
Voltage: +10 to -15% (Interphase voltage unbalance: 2% or less) (*6), Frequency: +5 to -5%
|
||||||||||
Required capacity with DCR [kVA] (*7) |
140
|
165
|
248
|
271
|
308
|
388
|
436
|
489
|
547
|
||
Braking | Torque [%] (*8) |
10 to 15%
|
|||||||||
Braking transistor |
-
|
||||||||||
EMC filter |
Compliant with EMC Directives, Emission and Immunity: Category C3 (2nd Env.) (EN61800-3:2004)
|
||||||||||
DC reactor (DCR) |
Option (*9)
|
||||||||||
Applicable safety standards |
UL508C, C22.2 No.14, EN50178:1997
|
||||||||||
Enclosure (IEC60529) |
IP00, UL open type
|
||||||||||
Cooling method |
Fan cooling
|
||||||||||
Weight/Mass [kg] |
62
|
64
|
103
|
103
|
144
|
144
|
(*2) Fuji 4-pole standard motor
(*3) Rated capacity is calculated by assuming the output rated voltage as 220V for 200V series and 440V for 400V series.
(*4) Output voltage cannot exceed the power supply voltage.
(*6) Voltage unbalance[%] = (Max. voltage [V] - Min. voltage [V])/Three-phase average voltage [V]×67(See IEC61800-3.) If this value is 2 to 3 %, use an optional AC reactor (ACR).
(*7) Required when a DC reactor (DCR) is used.
(*8) Average braking torque obtained by use of a motor. (Varies with the efficiency of the motor.)
(*9) A DC reactor (DCR) is an option. However, inverters with a capacity of 75 kW or above require a DCR to be connected. Be sure to connect it to those inverters.
Untuk informasi lebih lanjut silakan hubungi bagian Marketing kami, kami senang untuk membantu :
Hubungi | : Sales & Marketing |
Alamat |
: Simprug Plaza |
Jl. Simprug Raya Blok B.2 No.5 Cikarang Baru Jababeka II - Bekasi 17530 |
|
Telepon |
: 021 2851 8059 | 021 2851 8058 |
Mobile | : 0821 2570 0690 |
Fax | : 021 2851 8058 |
: sales@kitomaindonesia.com | marketing@kitomaindonesia.com | scales@kitomaindonesia.com | kitomascale@gmail.com |