Frenic Lift Fuji Electric 3-phase 400V
Kitoma Indonesia - Frenic Lift Fuji Electric 3-phase 400V
Elevator Inverter Frenic-Lift
Frenic Lift 3-phase 400V models
- FRN4.0LM1S-4EA : 3.7kW
- FRN5.5LM1S-4EA : 5.5kW
- FRN7.5LM1S-4EA : 7.5kW
- FRN11LM1S-4EA : 11kW
- FRN15LM1S-4EA : 15kW
- FRN18.5LM1S-4EA : 18.5kW
- FRN22LM1S-4EA : 22kW
- FRN30LM1S-4EA : 30kW
- FRN37LM1S-4EA : 37kW
- FRN45LM1S-4EA : 45kW
Optimum Exclusive Design for Passenger Elevators
- A braking circuit is built in the inverters of all the capacities
- Built-in PG feedback circuit is standard equipment.
- An optional keypad is available
Higher Performance
- Overload capacity : 200% for 10s
- Current response : 5 times greater than previous models (corporated with the G11UD series
- Reduction of torque ripple realizes low vibration
- Reduced roll-back during starting up
High performance vector control
- Current response (ACR) : 500Hz
- Speed control accuracy : ±0.01%
High overload capacity
200% of rated current for 10s (overload begins from 80% continous operation with a carrier frequency of 10kHz).
Specifications
Models |
Specifications | ||||||||||||
Type FRN***LM1S-4EA (*9) |
4.0 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | |||
Nominal applied motor [kW] (*1) | 3.7 | 5.5 | 7.5 |
11 |
15 | 18.5 |
22 |
30 | 37 | 45 | |||
Output ratings | Rated capacity [kVA] (*2) | 6.8 | 10.2 | 14 | 18 | 24 | 28 | 34 | 45 | 57 | 69 | ||
Rated voltage [V] (*3) | Three-phase, 380 to 480V, 50/60Hz | 3-phase, 380 to 460V, 50/60Hz | |||||||||||
Rated current [A] (*4) | 37.0 | 49.0 | 63.0 | 74.0 | 90.0 | ||||||||
Overload current rating [A] (10s) | 18.0 (3s) | 27.0 | 37.0 | 49.0 | 64.0 | 78.0 | 90.0 |
108 (5s) | 135 (5s) | 163 (5s) | |||
Rated frequency [Hz] | 50, 60Hz | ||||||||||||
Input rating | Nominal operation | Main power supply Phases, Voltage, Frequency |
Three-phase, 380 to 480V, 50/60Hz | ||||||||||
Auxiliary control power input Phases, Voltage, Frequency |
Single-phase, 200 to 480, 50/60Hz | Single-phase, 380 to 460V, 50/60Hz | |||||||||||
Permissible voltage and frequency fluctuation (*8) | Voltage: +10 to -15% (voltage imbalance within 2% or less *5), frequency: +5 to -5% | ||||||||||||
Rated input current [A] (*s) | With DCR | 7.5 | 10.6 | 14.4 | 21.1 | 28.8 | 35.5 | 42.2 | 57.0 |
68.5 |
83.2 | ||
Without DCR | 13.0 | 17.3 | 23.2 | 33.0 | 43.8 | 52.3 | 60.6 | 77.9 | 94.3 | 114 |
|||
Required power supply capacity [kVA] (*6) | 5.2 | 7.4 |
10 | 15 | 20 |
25 |
30 | 40 | 48 |
58 |
|||
Battery Operation | Main power supply | 48VDC or more in the direct current voltage conversion | |||||||||||
Auxillary Control power input (*10) |
Phases, Voltage, Frequency | Single-phase, 200 to 480V, 50/60Hz | Single-phase, 380 to 460V, 50/60Hz *10 | ||||||||||
Permissible Voltage and Frequency Fluctuations | Voltage: +10 to -15%, Frequency: +5 to -5% | ||||||||||||
Braking | Braking time [s] (*12) | 60 | |||||||||||
Braking duty-cycle (%ED) [%] (*12) | 50 | ||||||||||||
Minimum resistance which can be connected [Ω] (*8) | 96 | 64 |
48 | 24 | 24 | 16 | 16 | 10 | 10 | 8 |
|||
DC Reactore (DCR) | Option | ||||||||||||
Applicable safety standard | EN50178: 1997, EN954-1 EN61800-5-1, EN954-1 Category3 | ||||||||||||
Enclosure (IEC60529) | IP20 | ||||||||||||
Cooling method | Fan cooling | ||||||||||||
Weight/Mass [kg] | 3.0 | 5.6 | 5.7 | 7.5 | 11.1 | 11.2 | 11.7 | 24 | 33 | 34 |
(*1) Fuji Electric's 4-pole standard motor is used as an example of a applicable motor rating.
(*2) The rated capacity shows the case where the output voltage is 220V.
(*3) Voltages exceeding the power supply voltage cannot be output.
(*4) The rated current shows the case where the carrier frequency is 10kHz, ambient temperature is 45℃ or under, and the root mean squared current in cycle operation is 80% of the AC Drive's rated current. (or 16kHz at 40% ED)
(*5) Voltage imbalance [%] = (Max. voltage [V] - Min. voltage [V] / 3-phase average voltage [V] × 67 (See IEC61800-3).
(*6) Calculations were made based on a power supply capacity of 500 kVA (if the inverter capacity exceeds 50 kVA, the power supply capacity is 10 times the AC Drive capacity) and a connected power supply %X = 5%.
(*7) The AC Drive is equipped with a DC reactor (OCR).
(*8) These permissible fluctuations are tor the main power and the auxiliary control power input.
Untuk informasi lebih lanjut silakan hubungi bagian Marketing kami, kami senang untuk membantu :
Hubungi | : Sales & Marketing |
Alamat |
: Simprug Plaza |
Jl. Simprug Raya Blok B.2 No.5 Cikarang Baru Jababeka II - Bekasi 17530 Jawa Barat - Indonesia |
|
Telepon |
: 021 2851 8059 |
Mobile | : 0857 7664 0198 (Sales & Marketing) |
Fax | : 021 2851 8058 |
: sales@kitomaindonesia.com | marketing@kitomaindonesia.com | scales@kitomaindonesia.com | kitomascale@gmail.com |