Frenic Lift Fuji Electric 3-phase 200V

 

 

Kitoma Indonesia - Frenic Lift Fuji Electric 3-phase 200V

 

Elevator Inverter Frenic-Lift

Frenic Lift 3-phase 200V models

  • FRN5.5LM1S-2EA : 5.5kW
  • FRN7.5LM1S-2EA : 7.5kW
  • FRN11LM1S-2EA : 11kW
  • FRN15LM1S-2EA : 15kW
  • FRN18.5LM1S-2EA : 18.5kW
  • FRN22LM1S-2EA : 22kW

 

Optimum Exclusive Design for Passenger Elevators

  • A braking circuit is built in the inverters of all the capacities
  • Built-in PG feedback circuit is standard equipment.
  • An optional keypad is available


Higher Performance

  • Overload capacity : 200% for 10s
  • Current response : 5 times greater than previous models (corporated with the G11UD series
  • Reduction of torque ripple realizes low vibration
  • Reduced roll-back during starting up


High performance vector control

  • Current response (ACR) : 500Hz
  • Speed control accuracy : ±0.01%


High overload capacity
200% of rated current for 10s (overload begins from 80% continous operation with a carrier frequency of 10kHz).

 

Specifications


Models
Specifications
Type FRN***LM1S-2EA (*9)
2.2 7.5 11 15 18.5 22
Nominal applied motor [kW] (*1) 2.2 7.5
11
15
18.5
22
Output ratings Rated capacity [kVA] (*2) 10.2 14 18 24 28 34
Rated voltage [V] (*3) Three-phase 200V-220V, 50/60Hz
Rated current [A] (*4) 27.0 37.0 49.0 63.0 74.0 90.0
Overload capacity [A]
(Permisable energizing time)
54.0 74.0 98.0 126.0 148.0 180.0 (5s)
Rated frequency [Hz] 50, 60Hz
Input rating Nominal operation Main power supply Phases,
Voltage, Frequency
Three-phase, 200 to 240V, 50/60Hz
Auxiliary control power input
Phases, Voltage, Frequency
Single-phase, 200 to 240V, 50/60Hz
Voltage/frequency variations (*7) Voltage: +10 to -15% (Voltage imbalance within 2% or less *5), Frequency: +5 to -5%
Rated current [A] (*s) With DCR 21.1
28.8
42.2 57.6 71.0 84.4
Without DCR 31.5 42.7 60.7 80.1 97.0 112
Required power supply capacity [kVA] (*6) 7.4 10 15 20 25 30
Battery Operation Main power supply DC 24V or more in the direct current voltage conversion
Auxillary
Control power
input (*10) 
Phases, Voltage, Frequency Single-phase 200 to 240V, 50/60Hz
Voltage/frequency variations Voltage : +10 to -15%, Frequency: +5 to -5%
Braking Braking time [s] (*12) 60
Braking duty-cycle (%ED) [%] (*12) 50
Minimum resistance which can be connected [Ω] (*8) 15 10 7.5 6 4 3.5
DC Reactore (DCR) Option
Applicable safety standard EN50178: 1997, EN954-1 EN61800-5-1, EN954-1 Category3
Enclosure (IEC60529) IP20
Cooling method Fan cooling
Weight/Mass [kg] 5.7 5.9 7.4 11.0 11.3 11.8

(*1)    Fuji Electric's 4-pole standard motor is used as an example of a applicable motor rating.
(*2)    The rated capacity shows the case where the output voltage is 220V.
(*3)    Voltages exceeding the power supply voltage cannot be output.
(*4)    The rated current shows the case where the carrier frequency is 10kHz, ambient temperature is 45℃ or under, and the root mean squared current in cycle operation is 80% of the AC Drive's rated current. (or 16kHz at 40% ED)
(*5)    Voltage imbalance [%] = (Max. voltage [V] - Min. voltage [V] / 3-phase average voltage [V] × 67 (See IEC61800-3).
(*6)    Calculations were made based on a power supply capacity of 500 kVA (if the inverter capacity exceeds 50 kVA, the power supply capacity is 10 times the AC Drive capacity) and a connected power supply %X = 5%.
(*7)    The AC Drive is equipped with a DC reactor (OCR).
(*8)    These permissible fluctuations are tor the main power and the auxiliary control power input.

 

 

Untuk informasi lebih lanjut silakan hubungi bagian Marketing kami, kami senang untuk membantu :

 

Hubungi : Sales & Marketing
Alamat

: Simprug Plaza

 

  Jl. Simprug Raya Blok B.2 No.5 Cikarang Baru Jababeka II - Bekasi 17530 Jawa Barat - Indonesia

Telepon
: 021 2851 8059
Mobile : 0857 7664 0198 (Sales & Marketing)
Fax : 021 2851 8058
Email sales@kitomaindonesia.com  |  marketing@kitomaindonesia.com  |  scales@kitomaindonesia.com  | kitomascale@gmail.com