Mail Us at : sales@kitomaindonesia.com | Call Us 021 2851 8059

Inverter Hitachi SJ700B 3-phase 200V

 

 

Kitoma Indonesia - Inverter Hitachi SJ700B 3-phase 200V

 

High performance with Many useful Functions and User Friendly

 

Applicable motor rating 11kW - 75kW

 

SJ700B 3-phase 200V Models

  • SJ700B-110LFF : 11kW (15HP), 44A
  • SJ700B-150LFF : 15kW (20HP), 58A
  • SJ700B-185LFF : 18.5kW (25HP), 73A
  • SJ700B-220LFF : 22kW (30HP), 85A
  • SJ700B-300LFF : 30kW (40HP), 113A
  • SJ700B-370LFF : 37kW (50HP), 140A
  • SJ700B-450LFF : 45kW (60HP), 169A
  • SJ700B-550LFF : 55kW (75HP), 210A
  • SJ700B-750LFF : 75kW (100HP), 270A

 

SJ700B Features :

  • High starting Torque, Powerful Drive and easy setting
    • High starting torque of 200% or greater at 0.5Hz
  • Trip Avoidance function
  • Programming (EzSQ: Easy Sequence) function
  • Internal Option
  • Ease of Maintenance
  • Long life time components & Life time warning function
  • Easy operation
  • Network compatibility
  • Global standards
  • Environmental Friendliness

 

SJ700B Series : 3-phase 200V Standard Specifications

 

Model L700/SJ700B- 110LFF 150LFF 185LFF 220LFF 300LFF 370LFF 450LFF 550LFF 750LFF
Enclosure *1
IP20  
Applicable motor (4-pole, kW(HP)) *2
11(15) 15(20) 18.5(25) 22(30) 30(40) 37(50) 45(60) 55(75) 75(100)
Output Ratings 
  
Rated capacity
(KVA)
HP
200V 15.2 20.0 26.3 29.4 39.1
49.5 59.2 72.7 93.5
240V 18.2
24.1 31.5 35.3
46.9 59.4 71.0
87.2 112.2
Rated output current (A)  44 58  73 85 113 140 169 210 270
Overload capacity (output current)  120%,60sec
Rated output voltage *3 3-phase (3-wire) 200 to 240V (corresponding to input voltage)
Input Rating Rated input voltage (V) 3-phase 200 to 240V+10%, -15%, 50/60Hz±5%
Braking  Dynamic braking (Short-time) *4  Built-in BRD circuit (optional resistor) External dynamic braking unit(option)
Minimum value of resistor (Ω) 10 10 7.5 7.5 5 -
Vibration *5 5.9m/s2(0.6G), 10~55Hz 2.9m/s2(0.3G), 10~55Hz
Integrated EMC filter Built-in (EN61800-3 category C3)
Zero-phase Reactor Built-in
Weight (lbs.) 6(13.2) 6(13.2) 14(30.8) 14(30.8) 14(30.8) 22(48.4) 30(66) 30(66) 43(94.6)

*1 The protection method conforms to JIS C 0920(IEC60529).
*2  The applicable motor refers to Hitachi standard 3-phase motor (4-pole).
    To use other motors, be sure to prevent the rated motor current (50Hz) from exceeding the rated output current of the inverter.
*3  The output voltage decreases as the main power supply voltage decreases except for the use of AVR function.
*4  Braking resistor is not integrated in the inverter. Please install optional braking resistor or dynamic braking unit when large braking torque is required.
*5  Conforms to the test method specified in JIS C 60068-2-6:2010(IEC 60068-2-6:2007).

 

 

Untuk informasi lebih lanjut silakan hubungi bagian Marketing kami, kami senang untuk membantu :

 

Hubungi : Sales & Marketing
Alamat

: Simprug Plaza

 

  Jl. Simprug Raya Blok B.2 No.5 Cikarang Baru Jababeka II - Bekasi 17530

Telepon
: 021 2851 8059  |  021 2851 8058
Mobile : 0821 2570 0690
Fax : 021 2851 8058
Email sales@kitomaindonesia.com  |  marketing@kitomaindonesia.com  |  scales@kitomaindonesia.com  | kitomascale@gmail.com