Yaskawa U1000 Inverter 5HP-350HP
Kitoma Indonesia : Yaskawa U1000 Inverter 5HP-350HP
U1000 Industrial Matrix Drive
General Puprpose Drive
240V Power range
- 10 - 100HP (ND)
- 7.5 - 75HP (HD)
480V Power Range
- 7.5 - 350HP (ND)
- 5 - 300HP (HD)
Ambient Operating Temp
- -10°C to 50°C (OPEN TYPE IP00)
Certification
- UL, CSA, CE, RoHS
Standard I/O
- (8) Digital Inputs
- (3) Analog Inputs
- (1) Pulse Train Input
- (2) Safe Torque Off Inputs
- (4) Relay Output
- Analog Outputs
- (1) Pulse Train Output
- (1) Safe Torque Off Output
Standard Communications
- ModBus RTU
Control Options
- Ethernet/IP
- ModBus TCP/IP
- DeviceNet
- Profibus DP
- Profinet
- Expandable I/O
- Incremental Encoder
- Absolute Encoder
- Resolver
Mechanical Options
- Nema 1 Kit
- Exthernal Heatsink
Yaskawa U1000 Models
240V Class
CIMR-UU2A0028AUA
CIMR-UU2A0042AUA
CIMR-UU2A0054AUA
CIMR-UU2A0068AUA
CIMR-UU2A0081AUA
CIMR-UU2A0104AUA
CIMR-UU2A0130AUA
CIMR-UU2A0154AUA
CIMR-UU2A0192AUA
CIMR-UU2A0248AUA
480V Class
CIMR-UU4A0011AUA
CIMR-UU4A0014AUA
CIMR-UU4A0021AUA
CIMR-UU4A0027AUA
CIMR-UU4A0034AUA
CIMR-UU4A0040AUA
CIMR-UU4A0052AUA
CIMR-UU4A0065AUA
CIMR-UU4A0077AUA
CIMR-UU4A0096AUA
CIMR-UU4A0124AUA
CIMR-UU4A0156AUA
CIMR-UU4A0180AUA
CIMR-UU4A0216AUA
CIMR-UU4A0240AUA
CIMR-UU4A0302AUA
CIMR-UU4A0361AUA
CIMR-UU4A0414AUA
Features
- Full Regeneration
- Low Input Distortion Across a Wide Load and Speed Range
- IEEE-519 Compliant (<5% THD @ full load)
- Eco-Mode to Achieve Near Across-the-Line THD
- High Efficiency Design Provides Extra Energy Savings as Compared to Other Low Harmonic Solutions
- Near Unity True Power Factor at Full Load
- Integrated Input Fusing Provides 100kA SCCR
- Compact Design
- High Reliability with an MTBF of 28 Years
- Embedded Modbus RTU Communications
- Removable Terminal Block
- High Carrier Frequency (Low Motor Noise) Capability
- 0-400 Hz Output Frequency
- 120% Overload for 60 Seconds (ND)
- 150% Overload for 60 Seconds (HD)
- Multi-language LCD Display with Copy function
- Start into Spinning Load (Speed Search)
- Both Induction and Permanent Magnet Motor Control
- Closed or open loop vector control for outstanding regulation, torque production, and position control capability
- Continuous Auto-tuning optimizes performance by compensating for changes in motor temperature
- High Frequency Injection enables high precision open loop control of Interior Permanent Magnet Motors
- Fast acting current and voltage limiters help achieve continuous drive operation during periods of excessive demand
- Communication options for all major industrial networks provides high speed control and monitoring, reducing installation cost
- DriveWizard computer software and Application Sets for easy configuration
- Embedded Safe Torque Off minimizes downtime for applications requiring occasional intervention (SIL CL3, PLe, Category 3)
- Embedded function blocks, programmable with DriveWorks EZ, provide additional application flexibility and the opportunity to eliminate separate controllers
- USB Copy Unit and Keypad configuration storage provide speed and convenience for duplicate configuration of multiple drives
- Made with RoHS compliant materials
Specifications
Item
|
Specification
|
Overload Capacity | 150% for 60 sec. (HD), 120% for 60 sec. (ND) |
Output Frequency |
0~400 Hz |
Control Methods |
Open and Closed Loop Current Vector; |
Open and Closed Loop V/f | |
Motor Types | Induction |
Surface Permanent Magnet | |
Interior Permanent Magnet | |
Protective Design | IP00 (NEMA 1 kit available) |
Ambient Operating Temperature | -10 to +50C (IP00) |
-10 to +40C (with NEMA 1 kit) | |
Global Certifications | UL, CSA, CE, RoHS |
Standard I/O | (8) multi-function digital inputs (24Vdc) |
(3) multi-function analog inputs (0 +/- 10 Vdc, 4-20 mA) | |
(1) multi-function pulse inputs | |
(2) Safe Torque Off inputs | |
(1) fault relay output (form C) | |
(3) multi-function relay outputs (form A) |
|
(2) multi-function analog output (0 +/- 10 VDC, 4-20mA) | |
(1) multi-function pulse output | |
(1) safe Torque Off output (monitor) | |
I/O Expansion | 3 Analog Inputs -10 to +10V, 13 bit plus sign, 4 to 20mA |
16 Digital Inputs (+24V for BCD speed reference) | |
2 Analog Outputs (-10 to +10V, 11 bit magnitude) | |
8 Digital Outputs (6 transistor, 2 relay) | |
Feedback | Incremental |
Absolute (Stegmann, Heidenhain, Resolver) | |
Network Communication | Standard: Modbus RTU, RS-422/485, 115kbps |
Optional: EtherNet IP, DeviceNet, Modbus TCP/IP, PROFINET, PROFIBUS-DP | |
Speed Control Range | 1500:1 Closed Loop Vector (IM and PM Motors) |
200:1 Open Loop Vector (IM Motors) | |
100:1 Open Loop Vector (PM Motors) | |
Speed Control Accuracy | 0.02%: Closed Loop Vector; 0.2%; Open Loop Vector |
Speed Response | 250 Hz: Closed Loop Vector; 10 Hz: Open Loop Vector |
Function Block Diagrams | Up to 100 connections, 1ms program scan time |
Untuk informasi lebih lanjut silakan hubungi bagian Marketing kami, kami senang untuk membantu :
Hubungi | : Sales & Marketing |
Alamat |
: Simprug Plaza |
Jl. Simprug Raya Blok B.2 No.5 Cikarang Baru Jababeka II - Bekasi 17530 Jawa Barat - Indonesia |
|
Telepon |
: 021 2851 8059 |
Mobile | : 0857 7664 0198 (Sales & Marketing) | 0812 1165 3673 |
Fax | : 021 2851 8058 |
: sales@kitomaindonesia.com | marketing@kitomaindonesia.com | scales@kitomaindonesia.com | kitomascale@gmail.com |