nC1 LV 1-phase 110VAC

  • VFNC1S-1001P : 0.12 HP 0.7 FLA
  • VFNC1S-1002P : 0.25 HP 1.4 FLA
  • VFNC1S-1004P : 0.5 HP 2.4 FLA
  • VFNC1S-1007P : 1.0 HP 4.0 FLA


nC1 LV 1-phase 230VAC

  • VFNC1S-2002P : 0.25 HP 1.4 FLA
  • VFNC1S-2004P : 0.5 HP 2.4 FLA
  • VFNC1S-2007P : 1.0 HP 4.0 FLA
  • VFNC1S-2015P : 2.0 HP 7.5 FLA
  • VFNC1S-2022P : 3.0 HP 10 FLA


nC1 LV 3-phase 230VAC

  • VFNC1-2001P : 0.12 HP 0.7 FLA
  • VFNC1-2002P : 0.25 HP 1.4 FLA
  • VFNC1-2004P : 0.5 HP 2.4 FLA
  • VFNC1-2007P : 1.0 HP 4.0 FLA
  • VFNC1-2015P : 2.0 HP 7.5 FLA
  • VFNC1-2022P : 3.0 HP 10 FLA


nC1 LV 1-phase 230VAC Built-in RFI/EMI Filter

  • VFNC1S-2002PL : 0.25 HP 1.2 FLA
  • VFNC1S-2004PL : 0.5 HP 2.3 FLA
  • VFNC1S-2007PL : 1.0 HP 4.0 FLA
  • VFNC1S-2015PL : 2.0 HP 7.5 FLA
  • VFNC1S-2022PL : 3.0 HP 10.7 FLA

 

nC1 Standard Specifications
Range 1001P-1007P 2002P-2022P 2001PL-2022PL 2002P-2022P
Input Voltage Rating 120V / Single Phase 230V / Single Phase 230 V / Three Phase 230 V / Single Phase with RFI / EMI Filter
KW Range 0.1 - 0.75KW 0.2 - 2.2KW 0.1 - 2.2KW 0.2 - 2.2 KW
HP Range 1/8 - 1HP 1/4 - 3HP 1/8 - 3HP 1/4 - 3 HP
Overload Rating
150% for 60 seconds
Input Voltage Tolerance +10%, -15% +10%, -15% +10%, -15% +10%, -15%
Input Frequency Rating 50 / 60Hz 50 / 60Hz 50 / 60Hz 50 / 60Hz
Input Frequency Tolerance ±5% ±5% ±5% ±5%
Output Voltage Rating 230V, Three Phase
Color Munsel 5Y8 / 0.5
Control System Sinusoidal PWM Control
Output Voltage Range Adjustable within a range of 100 to 120% of the corrected supply voltage (200V), nonadjustable to any voltage higher than the input voltage
Output Frequency Range 0.5 - 200Hz, Default Setting: 0.5 - 80Hz, Max Frequency: 30 - 200Hz
Minimum Frequency Step 0.1Hz: Operation Panel Setting, 0.2Hz: Analog Input (when the Max Frequency is 100Hz)
Frequency Accuracy Digital Setting: within ±0.5% of the Max Frequency (-10 to +50°C)
Analog Setting: within ±1.0% of the Max Frequency (25°C ± 10°C )
V/f Characteristics V/f, Slip Frequency Compensation, Base Frequency, Base Frequency Voltage and Torque Boost
(adjustable amount)
Frequency Setting Signal Internal Pot on the Front Panel, External Frequency Signal (connectable to a volume with a rated impedance of 3-10 kΩ), VI Terminal (Input Impedance: 42 kΩ (Voltage: 0 - 10Vdc) or 250Ω (Current: 4 - 20 mAdc)). The frequency can be set arbitrarily using a two point setting.
Start-up & Jump Frequency Adjustable within a range of 0.5 - 10Hz, up to 1 frequency can be adjusted together with its widths
PWM Carrier Frequency Selectable from among 2, 4, 8, 12 and 16kHz (Standard Default Setting: 12kHz or 4kHz for models with a Built-In EMI Noise Filter)
Accel / Decel Time Two selectable Accel / Decel Times adjustable from 0.1 to 3000 seconds
Retry Operation Selectable number of retries (maximum 10 times)
If the protection function is activated, the retry function restarts on completion of a check of the main circuit.
Electric Control Charging of Capacitor (Deceleration Time can be shortened by activating Forced Shortened Deceleration mode.)
Dynamic Braking Braking Start Frequency: 0 to Max Frequency, Braking Rate: 0 to 100%, Braking Time: 0 to 20 seconds
Input Terminal Functions Forward / Reverse Run Input Signal, Jog Run Input Signal, Standby Signal, Preset-Speed Operation Input Signal, Reset Input Signal, etc.
Output Terminal Functions Frequency Lower Limit Output Signal, Frequency Upper Limit Output Signal, Low-Speed Detection Output Signal, Specified Speed Attainment Output Signal, etc., Open Collector, RY Output
Failure Detection Signal 1 Form C contact, Rated: 250Vac, 2A, cosΦ = 0.4
FM / AM Output PWM Output: (1mAdc full-scale DC ammeter or 7.5Vdc full-scale DC ammeter / Rectifier-type AC Voltmeter, 225% Current Max 1mAdc, 7.5Vdc full-scale)
Protective Function Stall Prevention, Current Limitation, Overcurrent, Output Short Circuit, Overvoltage, Overvoltage Limitation, Undervoltage, Ground Fault, Power Supply Phase Failure, Output Phase Failure Overload Protection by Electronic Thermal Function, Armature Overload at Start-up, Load-Side Overtorque at Start-up, Overheating Prevention, Detection of Analog Signal Break
Momentary Power Failure Protection Auto-Restart Control after momentary power failure
Electronic Thermal Characteristics Switching between Standard Motor / Constant- Torque VF Motor, Overload Trip, Overload Stall Selection
4-Digit, 7-Segment LED Frequency: Inverter Output Frequency
Alarm: Stall Alarm "C," Overvoltage Alarm "P," Overload Alarm "L," Overheat Alarm "H."
Status: Inverter Status (Frequency, Cause of Activation of Protective Function, Input / Output Voltage, Output Current, etc.) and Parameter Settings
Free-Unit Display: Arbitrary Unit (e.g. Rotating Speed) Corresponding to Output Frequency
Indicator Lamps indicating the inverter status by lighting, such as RUN lamp and PRG lamp
Use Environments Indoor- Altitude: 1000 m (maximum), not exposed to direct sunlight, corrosive gas, explosive gas or vibration (less than 5.9m x 2) (10 to 55 Hz)
Ambient Temperature -10 to +50˚C
Storage Temperature -20 to +65˚C
Relative Humidity 20 to 93% Non-Condensing

 

 

Untuk informasi lebih lanjut silakan hubungi bagian Marketing kami, kami senang untuk membantu :

 

Hubungi : Sales & Marketing
Alamat

: Simprug Plaza

 

  Jl. Simprug Raya Blok B.2 No.5 Cikarang Baru Jababeka II - Bekasi 17530 Jawa Barat - Indonesia

Telepon
: 021 2851 8059
Mobile : 0857 7664 0198 (Sales & Marketing)  |  0812 1165 3673
Fax : 021 2851 8058
Email [email protected]  |  [email protected]  |  [email protected]  | [email protected]