Analog type and Non-indicating type, set temperature by dial

Analog and non-indicating type, temperature controller which sets temperature by dial TOS/TOM/TOL series realizes provides wide range of product selection depending on temperature range so that suitable temperature control can be realized for user’s environment. Also, the series supports better user convenience by built-in burn out function and universe power range (only for TOS series).

 

Features

  • Non-indicating type
  • Setting temperature by Dial
  • Includes burn out function
  • Universal power: TOS

 

Specifications

 

Model TOS TOM TOL
Power supply 110-220VAC 50/60Hz 110/220VAC 50/60Hz
Allowable voltage range 90 to 110% of rated voltage
Power consumption Max. 2.2VA Max.3VA
Display method LED ON LED ON/OFF
Setting type Dial setting
Setting accuracy F.S. ±2%
Sensor input Thermocouples : K(CA), J(IC) / RTD : DPt100Ω
Input line resistance Thermocouples: Max. 100Ω, RTD: Allowable line resistance max. 5Ω per a wire
Control method ON/OFF Hysteresis : F.S. 0.5% ±0.2% fixed
Proportional Proportional band : F.S. 3% fixed, Period : 20sec. fixed
Control output • Relay output: 250VAC 2A 1c
• SSR drive voltage output :
12VDC ±3V Load 20mA Max.
• Relay output: 250VAC 3A 1c
• SSR drive voltage output: 12VDC ±3V 20mA Max..
Self-diagnosis Built-in burn out function (cut off output when sensor is disconnected)
Insulation resistance Min. 100MΩ (at 500VDC megger)
Dielectric strength 2000VAC 50/60Hz for 1 min.
Noise strength ±1kV the square wave noise(pulse width : 1㎲) by the noise simulator
Vibration Mechanical 0.75mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 1 hour
Malfunction 0.5mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 10 min.
Shock Mechanical 300m/s2(Approx. 30G) In each of X, Y, Z directions for 3 times
Malfunction 100m/s2(Approx. 10G) in each of X, Y, Z directions for 3 times
Relay life cycle Mechanical Min. 10,000,000 operations
  Electrical Min. 100,000 operations(250VAC 3Aat resistive load)
Environ-ment Ambient temperature -10 to 50℃, storage: -25 to 65℃
Ambient humidity 35 to 85%RH, storage: 35 to 85%RH
Aproval UL - -
Unit weight Approx. 104g Approx. 419g Approx. 426g

※F.S. is same with sensor measuring temperature range.
Ex) In case of using temperature is from 0 to 800℃, Full scale is "800".
※Environment resistance is rated at no freezing or condensation.

 

 

Untuk informasi lebih lanjut silakan hubungi bagian Marketing kami, kami senang untuk membantu :

 

Hubungi : Sales & Marketing
Alamat

: Simprug Plaza

 

  Jl. Simprug Raya Blok B.2 No.5 Cikarang Baru Jababeka II - Bekasi 17530 Jawa Barat - Indonesia

Telepon
: 021 2851 8059
Mobile : 0857 7664 0198 (Sales & Marketing)
Fax : 021 2851 8058
Email sales@kitomaindonesia.com  |  marketing@kitomaindonesia.com  |  scales@kitomaindonesia.com  | kitomascale@gmail.com