Kitoma Indonesia - LG magnetic Contactor C-5

 

  • 1NO+1NC or 2NO or 2NC Auxiliary contacts
  • Voltage: 220/ 380 V
  • Robust and compact design
  • Silver alloy contacts
  • Simple installation and maintenance
  • Quite and dependable
  • Long contactor life
  • Superior and interruption

 

Types and ratings
Type Max. motor capacity
(AC3 duty,kW)
Rated operational
current(A)
Rated thermal
current(A)
Auxiliary contact
200~240V 380~440V 200~240V 380~440V
C-5 5.5 7.5 20 17 30 1NO+1NC or
2NO or 2NC

Inching and plugging operations
Frame size Motor capacity(kW)
at 200~240V AC
Motor capacity(kW)
at 380~440V AC
50% inching operation 50% inching operation
Electrical life Electrical life
100,000
operations
500,000
operations
100,000
operations
500,000
operations
5 3 1.5 5.5 3

Rating of auxiliary contact
Frame Rating of applied Closed circuit breaking current(AC) (A) AC DC Rating of used current(A)
AC DC
Rating of used voltage(V) AC 11grade (Coil load) AC 13grade (Resistance load) Rating of used Voltage(V) DC 11grade (coil load) DC 14grade (Resistance load)
5 15 100 110V 10 15 24V 10 15
220V 48V 3 7.5
60 440V 6 110V 1 5
550V 220V 0.25 1.5

Performance
Frame Rating of used voltage(V) Rating of used current(A) Closed & breaking current capacity(A) Open/close frequency(more than round per hour) Life expectancy(more than 10,000 operations)
Making Breaking Mechanical Electrical
5 220 20 240 200 1800 1000 100

Application in 660V circuit
Frame TYPE 3øSpuirrelcage electric Motor (AC 3grade)
Rated capa. (kW) Rated operation current(A)
magnetic contactor motor starter 600~660V 600~660V
5 C-5 M-5 7.5 9

Operating magnetic coil
Coil voltage
Frame size Coil voltage frequency
5 110V 50Hz/110-120V 60Hz
220V 50Hz/220-240V 60Hz
380-400V 50Hz/400-440V 60Hz
Other voltages are available on request in 24V~600V range

Characteristic of magnetic coil
Frame size Power consumption
(VA)
Watt loss(W) Pick-up voltage(V) Drop-out voltage(V) Operating time(ms)(200V 50Hz)
Inrush sealed 200V
50Hz
220V
60Hz
200V
50Hz
220V
60Hz
200V
50Hz
220V
60Hz
Coil on→Main
contact on
Coil off→Main
contact off
5 90 14 2.9 2.9 115~145 125~170 80~110 95~130 7.2~16.8 5.1~14.2

 

 

Untuk informasi lebih lanjut silakan hubungi bagian Marketing kami, kami senang untuk membantu :

 

Hubungi : Sales & Marketing
Alamat

: Simprug Plaza

 

  Jl. Simprug Raya Blok B.2 No.5 Cikarang Baru Jababeka II - Bekasi 17530

Telepon
: 021 2851 8058  |  021 2851 8059  |  021 3725 0521  |  021 4448 9918
Mobile : 0821 2570 0690  |  0858 9027 2127  |  0877 8228 6338
Fax : 021 2851 8058
Email : sales@kitomaindonesia.com  |  marketing@kitomaindonesia.com  |  kitoma_kitoma@yahoo.co.id