Mail Us at : sales@kitomaindonesia.com | Call Us 021 2851 8059

Schneider Altivar 61 0.75kW 1HP 240V 3-phases

 

 

Schneider Altivar 61 0.75kW 1HP 240V 3-phases

ATV61H075M3 type


Variable Speed Drive ATV61 for Pumping and Ventilation Machine

Variable Speed Drive ATV61 - 0.75kW 1HP 200-240V IP20 - reinforced


Specification

  • Componen name : Alv 61
  • Motor power kW : 0.75kW 3-phases at 200-240V | 0.37kW 1-Phase at 200-240V
  • Motor powe HP : 0.5 HP single phases at 200-240V | 1 HP 3-phases at 200-240V
  • Power Supply Voltage : 200-240V (-15 10%)
  • Supply number of phases : 3-phases | 1-phases
  • Line Current :
    • 6.9 A for 200 V single phase 0.37 kW / 0.5 hp
    • 6.1 A for 200 V 3 phases 0.75 kW / 1 hp
    • 5.8 A for 240 V single phase 0.37 kW / 0.5 hp
    • 5.3 A for 240 V 3 phases 0.75 kW / 1 hp
  • EMC filter : Class C2 EMC filter integrated
  • Assembly style : With heat sink
  • Apparent power :
    • 2.2 kVA for 240 V 3 phases 0.75 kW / 1 hp
    • 1.4 kVA for 240 V single phase 0.37 kW / 0.5 hp
  • Maximum Prospective line Isc :
    • 5 kA single phase
    • 5 kA 3 phases
  • Maximum transient Current :
    • 5.7 A for 60 s 3 phases
    • 3.6 A for 60 s single phase
  • Nominal Switching frequency : 12kHz
  • Switching frequency : 
    • 12 - 16 kHz with derating factor
    • 1 - 16 kHz adjustable
  • Asynchronous motor control :
    • Voltage/frequency ratio, 2 points
    • Voltage/frequency ratio, 5 points
    • Flux vector control without sensor, standard
    • Voltage/frequency ratio - Energy Saving, quadratic U/f
  • Synchronous motor control profile : Vector control without sensor, standard
  • Communication port protocol :
    • CANopen
    • Modbus
  • Type of polarization : No impedance for Modbus
  • Option card :
    • Profibus DP V1 communication card
    • Profibus DP communication card
    • Multi-pump card
    • Modbus/Uni-Telway communication card
    • Modbus TCP communication card
    • Modbus Plus communication card
    • METASYS N2 communication card
    • LonWorks communication card
    • Interbus-S communication card
    • I/O extension card
    • Fipio communication card
    • Ethernet/IP communication card
    • DeviceNet communication card
    • Controller inside programmable card
    • CC-Link communication card
    • BACnet communication card
    • APOGEE FLN communication card 
    • Modbus

 

Complementary

Product destination Asynchronous motors
Synchronous motors
Power supply voltage limits 170...264 V
Power supply frequency 50...60 Hz (- 5...5 %)
Power supply frequency limits 47.5...63 Hz
Continuous output current 4.8 A at 12 kHz, 230 V 3 phases
3 A at 12 kHz, 230 V single phase
Speed drive output frequency 0.1...1000 Hz
Speed range 1...100 in open-loop mode, without speed feedback
Speed accuracy +/- 10 % of nominal slip for 0.2 Tn to Tn torque variation without speed feedback
Torque accuracy +/- 15 % in open-loop mode, without speed feedback
Transient overtorque 130 % of nominal motor torque, +/- 10 % for 60 s
Braking torque 30 % without braking resistor
<= 125 % with braking resistor
Regulation loop Frequency PI regulator
Motor slip compensation Adjustable
Automatic whatever the load
Can be suppressed
Not available in voltage/frequency ratio (2 or 5 points)
Diagnostic 1 LED red presence of drive voltage
Output voltage <= power supply voltage
Electrical isolation Between power and control terminals
Type of cable for mounting in an enclosure Without mounting kit : 1-strand IEC cable at 45 °C, copper 90 °C XLPE/EPR
Without mounting kit : 1-strand IEC cable at 45 °C, copper 70 °C PVC
With UL Type 1 kit : 3-strand UL 508 cable at 40 °C, copper 75 °C PVC
With an IP21 or an IP31 kit : 3-strand IEC cable at 40 °C, copper 70 °C PVC
Electrical connection L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB terminal 6 mm² / AWG 8
AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR terminal 2.5 mm² / AWG 14
Tightening torque L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB 1.4 N.m / 12.3 lb.in
AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR 0.6 N.m
Supply Internal supply 24 V DC (21...27 V), <= 200 mA for overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <= 10 mA for overload and short-circuit protection
External supply 24 V DC (19...30 V), 30 W
Analogue input number 2
Analogue input type AI2 software-configurable voltage 0...10 V DC, input voltage 24 V max, impedance 30000 Ohm, resolution 11 bits
AI2 software-configurable current 0...20 mA, impedance 242 Ohm, resolution 11 bits
AI1-/Al1+ bipolar differential voltage +/- 10 V DC, input voltage 24 V max, resolution 11 bits + sign
Sampling time Discrete input LI6 (if configured as logic input) 2 ms, +/- 0.5 ms
Discrete input LI1...LI5 2 ms, +/- 0.5 ms
Analog output AO1 2 ms, +/- 0.5 ms
Analog input Al2 2 ms, +/- 0.5 ms
Analog input AI1-/Al1+ 2 ms, +/- 0.5 ms
Absolute accuracy precision AO1 +/- 1 % for a temperature variation 60 °C
AI2 +/- 0.6 % for a temperature variation 60 °C
AI1-/Al1+ +/- 0.6 % for a temperature variation 60 °C
Linearity error AO1 +/- 0.2 %
AI2 +/- 0.15 % of maximum value
AI1-/Al1+ +/- 0.15 % of maximum value
Analogue output number 1
Analogue output type AO1 software-configurable logic output 10 V, <= 20 mA
AO1 software-configurable voltage, analogue output range 0...10 V DC, impedance 470 Ohm, resolution 10 bits
AO1 software-configurable current, analogue output range 0...20 mA, impedance 500 Ohm, resolution 10 bits
Discrete output number 2
Discrete output type (R2A, R2B) configurable relay logic NO, electrical durability 100000 cycles
(R1A, R1B, R1C) configurable relay logic NO/NC, electrical durability 100000 cycles
Maximum response time R2A, R2B <= 7 ms, tolerance +/- 0.5 ms
R1A, R1B, R1C <= 7 ms, tolerance +/- 0.5 ms
<= 100 ms in STO (Safe Torque Off)
Minimum switching current Configurable relay logic 3 mA at 24 V DC
Maximum switching current R1, R2 on resistive load, 5 A at 30 V DC, cos phi = 1, L/R = 0 ms
R1, R2 on resistive load, 5 A at 250 V AC, cos phi = 1, L/R = 0 ms
R1, R2 on inductive load, 2 A at 30 V DC, cos phi = 0.4, L/R = 7 ms
R1, R2 on inductive load, 2 A at 250 V AC, cos phi = 0.4, L/R = 7 ms
Discrete input number 7
Discrete input type (PWR) safety input, 24 V DC, voltage limits <= 30 V, impedance 1500 Ohm
(LI6) switch-configurable PTC probe, 0...6, impedance 1500 Ohm
(LI6) switch-configurable, 24 V DC, voltage limits <= 30 V, with level 1 PLC, impedance 3500 Ohm
(LI1...LI5) programmable, 24 V DC, voltage limits <= 30 V, with level 1 PLC, impedance 3500 Ohm
Discrete input logic LI6 (if configured as logic input) positive logic (source), < 5 V (state 0), > 11 V (state 1)
LI6 (if configured as logic input) negative logic (sink), > 16 V (state 0), < 10 V (state 1)
LI1...LI5 positive logic (source), < 5 V (state 0), > 11 V (state 1)
LI1...LI5 negative logic (sink), > 16 V (state 0), < 10 V (state 1)
Acceleration and deceleration ramps Automatic adaptation of ramp if braking capacity exceeded, by using resistor
Linear adjustable separately from 0.01 to 9000 s
S, U or customized
Braking to standstill By DC injection
Protection type Motor thermal protection
Motor power removal
Motor motor phase break
Drive thermal protection
Drive short-circuit between motor phases
Drive power removal
Drive overvoltages on the DC bus
Drive overheating protection
Drive overcurrent between output phases and earth
Drive line supply undervoltage
Drive line supply overvoltage
Drive input phase breaks
Drive break on the control circuit
Drive against input phase loss
Drive against exceeding limit speed
Insulation resistance > 1 mOhm at 500 V DC for 1 minute to earth
Frequency resolution Display unit 0.1 Hz
Analog input 0.024/50 Hz
Type of connector Male SUB-D 9 on RJ45 for CANopen
1 RJ45 for Modbus on terminal
1 RJ45 for Modbus on front face
Physical interface 2-wire RS 485 for Modbus
Transmission frame RTU for Modbus
Transmission rate 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen
9600 bps, 19200 bps for Modbus on front face
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal
Data format 8 bits, odd even or no configurable parity for Modbus on terminal
8 bits, 1 stop, even parity for Modbus on front face
Number of addresses 1...247 for Modbus
1...127 for CANopen
Method of access Slave for CANopen
Marking CE
Operating position Vertical +/- 10 degree
Product weight 3 kg
Width 130 mm
Height 230 mm
Depth 175 mm

 

 

Untuk informasi lebih lanjut silakan hubungi bagian Marketing kami, kami senang untuk membantu :

 

Hubungi : Sales & Marketing
Alamat

: Simprug Plaza

 

  Jl. Simprug Raya Blok B.2 No.5 Cikarang Baru Jababeka II - Bekasi 17530 Jawa Barat - Indonesia

Telepon
: 021 2851 8059
Mobile : 0857 7664 0198 (Sales & Marketing)  |  0812 1165 3673
Fax : 021 2851 8058
Email sales@kitomaindonesia.com  |  marketing@kitomaindonesia.com  |  scales@kitomaindonesia.com  | kitomascale@gmail.com