Servo Motor Omron G5 Series AC Servomotor
Kitoma Indonesia - Servo Motor Omron G5 Series AC Servomotor tipe R88M-K, R88D-KN-ECT
AC Servomotor Seri G5 memiliki koneksi langsung ke controller NJ melalui EtherCAT. Pelanggan dapat merancang lebih cepat, sistem otomasi kontrol mesin yang lebih advance.
Fitur :
- High-accuracy positioning with fully-closed control.
- Servo Drives for 400VAC globally widens applicable systems and environment, including large-scale equipment.
- Safe design and Safe Torque Off (STO) function.
- Vibration can be suppressed in acceleration/deceleration even in low-rigidity mechanical systems.
Spesifikasi :
AC Servo Drives
General Specifications
Item | Specifications | ||
---|---|---|---|
Ambient operating temperature and operating humidity |
0 to 55°C, 90% RH max. (with no condensation) | ||
Storage ambient temperature and humidity |
.20 to 65°C, 90% RH max. (with no condensation) | ||
Operating and storage atmosphere | No corrosive gases | ||
Vibration resistance | 10 to 60 Hz and at an acceleration of 5.88 m/s2 or less (Not to be run continuously at a resonance point) |
||
Insulation resistance | Between power supply terminals/power terminals and FG terminal: 0.5 MΩ min. (at 500 VDC) |
||
Dielectric strength | Between power supply/power line terminals and FG terminal: 1,500 VAC for 1 min at 50/60 Hz |
||
Protective structure | Built into panel | ||
International standard | EC Directives | EMC Directive | EN 55011, EN 61000-6-2, IEC 61800-3 |
Low Voltage Directive |
EN 61800-5-1 | ||
Machinery Directives |
EN954-1 (Cat.3), EN ISO 13849-1: 2008 (Category 3) (PLc,d), ISO 13849-1: 2006 (Category 3) (PLc,d), EN61508 (SIL2), EN62061 (SIL2), EN61800-5-2 (STO), IEC61326-3-1 (SIL2) |
||
UL standards | UL 508C | ||
CSA standards | CSA22.2 No. 14 |
Note: 1. The above items reflect individual evaluation testing. The results may differ under compound conditions.
Note: 2. Always disconnect all connections to the Servo Drive before you perform insulation resistance tests on it. If you perform an insulation resistance test while the Servo Drive is connected, the Servo Drive may be damaged. Never perform dielectric strength tests on the Servo Drive. Failure to follow this precaution may result in damaging internal elements.
Note: 3. Depending on the operating conditions, some Servo Drive parts will require maintenance. For details, refer to the G5 series USER'S MANUAL. Confirm the Manual No. that is listed in Related Manuals.
Untuk informasi lebih lanjut silakan hubungi bagian Marketing kami, kami senang untuk membantu :
Hubungi | : Sales & Marketing |
Alamat |
: Simprug Plaza |
Jl. Simprug Raya Blok B.2 No.5 Cikarang Baru Jababeka II - Bekasi 17530 |
|
Telepon |
: 021 2851 8058 | 021 2851 8059 | 021 3725 0521 | 021 4448 9918 |
Mobile | : 0821 2570 0690 | 0858 9027 2127 | 0877 8228 6338 |
Fax | : 021 2851 8058 |
: sales@kitomaindonesia.com | marketing@kitomaindonesia.com | kitoma_kitoma@yahoo.co.id |