AC Servo System SV Series

  • 3-phase
  • 200-230 VAC
  • 5kW


Pulse train type

Pulse/analog input
 

 

Specification

 

Model

SV-500P2

General specifications

Capacity

5.0kW

Input power supply

Allowable voltage fluctuation

Main circuit/control circuit

AC170 to 253V

Allowable instantaneous outage time

Control circuit

approx 100ms

Operating environment

Ambient operating/storage humidity

90%RH or less(no condensation)

Approved standards

CE marking

Low-voltage directive

EN50178

Weight

approx 4.7kg

Power supply/current capacity and power loss

Maximum applicable motor capacity (W)

Single-phase 100 VAC

-

Three-phase 200 VAC

5.0k

Single-phase 200 VAC

-

Power capacity (VA) per amplifier

Single-phase 100 VAC

Three-phase 200 VAC

7500

Single-phase 200 VAC

-

Output current (Arms)

Continuous

Single-phase 100 VAC

Three-phase 200 VAC

32.9

Single-phase 200 VAC

-

Maximum

Single-phase 100 VAC

Three-phase 200 VAC

84

Single-phase 200 VAC

-

Main circuit power loss (W)

Single-phase 100 VAC

Three-phase 200 VAC

263.7

Single-phase 200 VAC

-

Built-in regenerative resistor power loss (W)

Single-phase 100 VAC

Three-phase 200 VAC

36

Single-phase 200 VAC

-

Control circuit power loss (W)

Single-phase 100 VAC

Three-phase 200 VAC

27

Single-phase 200 VAC

-

Total power loss (W)

Single-phase 100 VAC

Three-phase 200 VAC

326.7

Single-phase 200 VAC

-

Input rated current

Main circuit (Arms)

Single-phase 100 VAC

Three-phase 200 VAC

25

Single-phase 200 VAC

-

Control circuit (Arms)

Single-phase 100 VAC

Three-phase 200 VAC

0.3

Single-phase 200 VAC

-

Rush current*1

Main circuit (A)

Single-phase 100 VAC

Three-phase 200 VAC

65.5

Single-phase 200 VAC

-

Control circuit (A)

Single-phase 100 VAC

Three-phase 200 VAC

33

Single-phase 200 VAC

-

Communication specifications (MECHATROLINK-II type only)

MECHATROLINK communication

Station address

Transmission speed

MECHATROLINK-II

MECHATROLINK-I

Transmission frequency

MECHATROLINK-II

I/O specifications

MECHATROLINK-II type

Control I/O

Input signal

Communication specifications (MECHATROLINK-II type only)

MECHATROLINK communication

Transmission frequency

MECHATROLINK-I

Transmission byte number

MECHATROLINK-II

I/O specifications

MECHATROLINK-II type

Control I/O

Output signal

Communication specifications (MECHATROLINK-II type only)

MECHATROLINK communication

Transmission byte number

MECHATROLINK-I

Command method

Operation specifications

I/O specifications

MECHATROLINK-II type

Encoder division pulse output

Communication specifications (MECHATROLINK-II type only)

Command method

Command input

I/O terminal specifications and wiring

General-purpose input (DI-1)

Maximum input voltage

DC26.4V

I/O specifications

Pulse/analog input type

Control I/O

Input signal

13ch

I/O terminal specifications and wiring

General-purpose input (DI-1)

Input rated voltage

DC24V (5mA)

Minimum ON voltage

DC19V

I/O specifications

Pulse/analog input type

Control I/O

Output signal

5ch

I/O terminal specifications and wiring

General-purpose input (DI-1)

Maximum OFF current

0.1mA

2-wire method compatible input (DI-2)

Maximum input voltage

DC26.4V

Input rated voltage

DC24V (9mA)

Minimum ON voltage

DC19V

Maximum OFF current

1.5mA

2-wire method compatible high-speed input (DI-3)

Maximum input voltage

-

Input rated voltage

Minimum ON voltage

Maximum OFF current

Item

Common ground

General-purpose output (DO-1)

Rated load

DC30V(30mA)

Leakage current (at OFF)

0.1mA

Residual voltage (at ON)

DC1.6V or less

Z phase open-collector output (DO-2)

Rated load

DC30V(30mA)

Leakage current (at OFF)

0.1mA

Residual voltage (at ON)

DC1.2V or less

Output frequency

50kHz

Pulse input (DI-P)

Maximum input voltage

Open-collector (R1 resistance value)*2

DC30V

Open-collector (R1 resistance value)*3

DC15V

DC6.25V

Input rated voltage

DC24V

DC12V

DC5V

Minimum ON voltage

18.3V

9.9V

4.2V

Maximum OFF current

Open-collector (R1 resistance value) recommended input current*4

01.mA

Response frequency

200kHz

*1 When used with the amount of current listed above, the duration of the rush current is 20 ms or lower.
*2 recommended input current: 7 to 15 mA
*3 recommended input current: 7 to 15 mA
*4 7 to 15 mA

 

 

Untuk informasi lebih lanjut silakan hubungi bagian Marketing kami, kami senang untuk membantu :

 

Hubungi : Sales & Marketing
Alamat

: Simprug Plaza

 

  Jl. Simprug Raya Blok B.2 No.5 Cikarang Baru Jababeka II - Bekasi 17530

Telepon
: 021 2851 8058  |  021 2851 8059  |  021 3725 0521  |  021 4448 9918
Mobile : 0821 2570 0690  |  0858 9027 2127  |  0877 8228 6338
Fax : 021 2851 8058
Email : sales@kitomaindonesia.com  |  marketing@kitomaindonesia.com  |  kitoma_kitoma@yahoo.co.id