SV-300P2 Keyence Servo 3-phase 230VAC 3kW
Kitoma Indonesia - SV-300P2 Keyence Servo Amplifier 3-phase 230VAC 3kW
AC Servo System SV Series
- 3-phase
- 200 - 230 VAC
- 3kW
Pulse train type
Pulse/analog input
Specification
Model |
SV-300P2 |
|||
General specifications |
Capacity |
3.0kW |
||
Input power supply |
Allowable voltage fluctuation |
Main circuit/control circuit |
AC170 to 253V |
|
Allowable instantaneous outage time |
Control circuit |
approx 100ms |
||
Operating environment |
Ambient operating/storage humidity |
90%RH or less(no condensation) |
||
Approved standards |
CE marking |
Low-voltage directive |
EN50178 |
|
Weight |
approx 2.9kg |
|||
Power supply/current capacity and power loss |
Maximum applicable motor capacity (W) |
Single-phase 100 VAC |
- |
|
Three-phase 200 VAC |
3.0k |
|||
Single-phase 200 VAC |
- |
|||
Power capacity (VA) per amplifier |
Single-phase 100 VAC |
|||
Three-phase 200 VAC |
5900 |
|||
Single-phase 200 VAC |
- |
|||
Output current (Arms) |
Continuous |
Single-phase 100 VAC |
||
Three-phase 200 VAC |
19.6 |
|||
Single-phase 200 VAC |
- |
|||
Maximum |
Single-phase 100 VAC |
|||
Three-phase 200 VAC |
56 |
|||
Single-phase 200 VAC |
- |
|||
Main circuit power loss (W) |
Single-phase 100 VAC |
|||
Three-phase 200 VAC |
113.8 |
|||
Single-phase 200 VAC |
- |
|||
Built-in regenerative resistor power loss (W) |
Single-phase 100 VAC |
|||
Three-phase 200 VAC |
16 |
|||
Single-phase 200 VAC |
- |
|||
Control circuit power loss (W) |
Single-phase 100 VAC |
|||
Three-phase 200 VAC |
22 |
|||
Single-phase 200 VAC |
- |
|||
Total power loss (W) |
Single-phase 100 VAC |
|||
Three-phase 200 VAC |
151.8 |
|||
Single-phase 200 VAC |
- |
|||
Input rated current |
Main circuit (Arms) |
Single-phase 100 VAC |
||
Three-phase 200 VAC |
15 |
|||
Single-phase 200 VAC |
- |
|||
Control circuit (Arms) |
Single-phase 100 VAC |
|||
Three-phase 200 VAC |
0.25 |
|||
Single-phase 200 VAC |
- |
|||
Rush current*1 |
Main circuit (A) |
Single-phase 100 VAC |
||
Three-phase 200 VAC |
33 |
|||
Single-phase 200 VAC |
- |
|||
Control circuit (A) |
Single-phase 100 VAC |
|||
Three-phase 200 VAC |
33 |
|||
Single-phase 200 VAC |
- |
|||
Communication specifications (MECHATROLINK-II type only) |
MECHATROLINK communication |
Station address |
||
Transmission speed |
MECHATROLINK-II |
|||
MECHATROLINK-I |
||||
Transmission frequency |
MECHATROLINK-II |
|||
I/O specifications |
MECHATROLINK-II type |
Control I/O |
Input signal |
|
Communication specifications (MECHATROLINK-II type only) |
MECHATROLINK communication |
Transmission frequency |
MECHATROLINK-I |
|
Transmission byte number |
MECHATROLINK-II |
|||
I/O specifications |
MECHATROLINK-II type |
Control I/O |
Output signal |
|
Communication specifications (MECHATROLINK-II type only) |
MECHATROLINK communication |
Transmission byte number |
MECHATROLINK-I |
|
Command method |
Operation specifications |
|||
I/O specifications |
MECHATROLINK-II type |
Encoder division pulse output |
||
Communication specifications (MECHATROLINK-II type only) |
Command method |
Command input |
||
I/O terminal specifications and wiring |
General-purpose input (DI-1) |
Maximum input voltage |
DC26.4V |
|
I/O specifications |
Pulse/analog input type |
Control I/O |
Input signal |
13ch |
I/O terminal specifications and wiring |
General-purpose input (DI-1) |
Input rated voltage |
DC24V (5mA) |
|
Minimum ON voltage |
DC19V |
|||
I/O specifications |
Pulse/analog input type |
Control I/O |
Output signal |
5ch |
I/O terminal specifications and wiring |
General-purpose input (DI-1) |
Maximum OFF current |
0.1mA |
|
2-wire method compatible input (DI-2) |
Maximum input voltage |
DC26.4V |
||
Input rated voltage |
DC24V (9mA) |
|||
Minimum ON voltage |
DC19V |
|||
Maximum OFF current |
1.5mA |
|||
2-wire method compatible high-speed input (DI-3) |
Maximum input voltage |
- |
||
Input rated voltage |
||||
Minimum ON voltage |
||||
Maximum OFF current |
||||
Item |
||||
Common ground |
||||
General-purpose output (DO-1) |
Rated load |
DC30V(30mA) |
||
Leakage current (at OFF) |
0.1mA |
|||
Residual voltage (at ON) |
DC1.6V or less |
|||
Z phase open-collector output (DO-2) |
Rated load |
DC30V(30mA) |
||
Leakage current (at OFF) |
0.1mA |
|||
Residual voltage (at ON) |
DC1.2V or less |
|||
Output frequency |
50kHz |
|||
Pulse input (DI-P) |
Maximum input voltage |
Open-collector (R1 resistance value)*2 |
DC30V |
|
Open-collector (R1 resistance value)*3 |
DC15V |
|||
DC6.25V |
||||
Input rated voltage |
DC24V |
|||
DC12V |
||||
DC5V |
||||
Minimum ON voltage |
18.3V |
|||
9.9V |
||||
4.2V |
||||
Maximum OFF current |
Open-collector (R1 resistance value) recommended input current*4 |
01.mA |
||
Response frequency |
200kHz |
|||
*1 When used with the amount of current listed above, the duration of the rush current is 20 ms or lower. |
Untuk informasi lebih lanjut silakan hubungi bagian Marketing kami, kami senang untuk membantu :
Hubungi | : Sales & Marketing |
Alamat |
: Simprug Plaza |
Jl. Simprug Raya Blok B.2 No.5 Cikarang Baru Jababeka II - Bekasi 17530 |
|
Telepon |
: 021 2851 8058 | 021 2851 8059 | 021 3725 0521 | 021 4448 9918 |
Mobile | : 0821 2570 0690 | 0858 9027 2127 | 0877 8228 6338 |
Fax | : 021 2851 8058 |
: sales@kitomaindonesia.com | marketing@kitomaindonesia.com | kitoma_kitoma@yahoo.co.id |