Loadcell Converter Unipulse LC240
Kitoma Indonesia - Loadcell Converter Unipulse LC240
Unipulse LC240 LC240 is a loadcell converter with the large capacity that allows up to 4 loadcells to be driven.
LC240 is a low-drift loadcell converter designed for loadcells.
With a U300DC preamplifier with a proven track record in stability adopted for the head amplifier, it realizes low drift and low noise features.
The bridge excitation power supply can be adjusted to 6 different levels besides the large capacity that allows up to 4 loadcells to be driven in parallel. LC240 is capable of loadcell converter that is standard equipped with the calibration function and current output.
Specifications
Excitation voltage | 10V DC ±0.5%, Output current: within 120mA…..Standard specification (Up to 4 loadcells at 350Ω can be parallel-connectable.) 2.5, 2.9, 4, 5, 6,6V DC ±0.6% (Switching over via DIP switch) Output current: within 60mA |
---|---|
Zero adjustment range | 0 - approx. 2mV/V
|
Gain adjustment range |
0.45mV/V - 3.0mV/V 0.225mV/V - 1.5 mV/V (Range can be changed by selecting an internal switch)
|
Accuracy |
|
Output signal |
Voltage output: 0 -±10V, Load resistance: 2kΩ or more, Output resistance: 0.2Ω or less Current output: 4 - 20mA, Load resistance: 500Ω or less |
Low-pass filter | Low-pass filter (-6dB/oct.) Approx. 1 Hz / -3dB….Standard specification |
Calibration value | 1 mV/V ±0.2%....Standard specification |
Power supply voltage | 100V AC ±10%, 50/60 Hz |
Power consumption | approx. 5VA |
Operating conditions | Temperature: Working temperature range -10 - +40°C Humidity: 85% RH or less (non-condensing) |
External dimensions | 44.6 (W) x 110 (H) x 185 (D) [mm] (protruding parts not included) |
Weight | Approx. 820 g |
Accessories |
|
* Nonstandard specifications can support the following: (Please specify when ordering.)
- Current output: 2 -10 mA, Load resistance: 1kO or less
- Filter: 10, 100, 1kHz , other
- Calibration value: 0.5mV/V
Option
Configurable parameter | Standard specification | Changeable specification |
Current output | 4 - 20mA, Load resistance: 500Ω or less | 2 - 10mA, Load resistance: 1kΩ |
---|---|---|
Filter | 1 Hz | 10 Hz, 100 Hz, 1kHz |
Calibration value | 1mV/V | 0.5mV/V |
Optional accessories
Model | Description |
POT03 | Potentiometer for external zero adjustment |
---|
Untuk informasi lebih lanjut silakan hubungi bagian Marketing kami, kami senang untuk membantu :
Hubungi | : Sales & Marketing |
Alamat |
: Simprug Plaza |
Jl. Simprug Raya Blok B.2 No.5 Cikarang Baru Jababeka II - Bekasi 17530 |
|
Telepon |
: 021 2851 8058 | 021 2851 8059 | 021 3725 0521 | 021 4448 9918 |
Mobile | : 0821 2570 0690 | 0858 9027 2127 | 0877 8228 6338 |
Fax | : 021 2851 8058 |
: scales@kitomaindonesia.com | kitomascale@gmail.com | timbangan@kitomaindonesia.com |