Loadcell Interface Unipulse F130 for PLC

 

 

Kitoma Indonesia - Loadcell Interface Unipulse F130 for PLC

Loadcell Interface for OMRON SYSMAC CJ1/CJ2/NJ

Waste in production line is thoroughly eliminated to realize substantial cost reductions and high added value.

F130 is a loadcell interface that allows direct plug-in to OMRON’s general-purpose PLC SYSMAC CJ1/CJ2/NJ for strain gauge type sensors. Sensor output is quickly loaded as a digital value, and directly output to the CPU.
Waste in production line is thoroughly eliminated to realize substantial cost reductions and high added value by reducing measurement system development time and improving maintenance management, modification and serviceability.

About the connection propriety of NJ series
CPU unit (NJ301/NJ501): ver.1.06 or later connectable
Sysmac Studio: ver.1.07 or later connectable

 

Specifications

 

GENERAL SPECIFICATIONS
Consumption current DC5V Approx.0.46A(At excitation voltage DC10V, single 350Ω sensor)
Operating conditions Temperature: Operation temperature 0℃ - +55℃ Accuracy compensation applicable temperature 0℃ - +40℃ Storage temperature -20℃ - +75℃
Humidity: 90%RH or lower(non-condensing)
External dimensions 31(W)× 90(H)× 65(D)mm(protrusion excluded)
Weight Approx.160g

 

ANALOG SECTION
Excitation voltage DC10V±5%, Output current: within 30mA (single 350Ω sensor)
DC2.5V±5%, Output current: within 30mA (single 120Ω sensor or four 350Ω sensors in parallel)
Signal input range -3.0~+3.0mV/V
Equivalent input calibration range 0.5~3.0mV/V
Zero and gain adjustment range Automatic adjustment via digital processing
Accuracy Non-linearity : within 0.02%/FS ±1digit (at 3.0mV/V input)
Zero drift: within 0.5μV/℃ RTI
Gain drift: Within 25ppm/℃
A/D converter Speed: 3000 times/sec.
Resolution: 24bit(binary) 1/10000 to 1.0mV/V input
Analog filter Low pass filter(-6dB/oct.)Selectable at 30, 100, 300, 1000Hz

 

DISPLAY SECTION
Status LED RUN(Green)……Turns on when Normal operation
ERC(Red)……Turns on when an alarm occurs or blinks when an error occurs in the F130
ERH(Red)……Turns on when an alarm occurs in data exchange with the CPU unit

 

SETTING SECTION
Unit No. rotary switch High performance I/O unit No. setting: 0 - 95 unit
Setting method Made from the CPU unit via the data memory(DM) area defined for the F130.
Set value Storage Calibration value: Stored in NOV RAM (non-volatile RAM)
Set value: Measurement stats with the set values (DM area) written from the CPU unit after power-on. (Not stored on the F130 side)

 

 

Untuk informasi lebih lanjut silakan hubungi bagian Marketing kami, kami senang untuk membantu :

 

Hubungi : Sales & Marketing
Alamat

: Simprug Plaza

 

  Jl. Simprug Raya Blok B.2 No.5 Cikarang Baru Jababeka II - Bekasi 17530

Telepon
: 021 2851 8058  |  021 2851 8059  |  021 3725 0521  |  021 4448 9918
Mobile : 0821 2570 0690  |  0858 9027 2127  |  0877 8228 6338
Fax : 021 2851 8058
Email : scales@kitomaindonesia.com  |  kitomascale@gmail.com  |  timbangan@kitomaindonesia.com