Digital Indicator Unipulse F805A
Kitoma Indonesia - Menyediakan Digital Indicator Unipulse F805A
LCD Touch Panel Display All-in-One Type Weighing Controller
F805A is a full-fledged device of an all-in-one type that deserves to be called the top-of-the-line loadcell controller.
F805A adopts a color LCD touch panel which enables simple and comfortable operation by greatly enhancing the visibility of weight display, various setting values display and status display. It provides high-speed A/D conversion and digital processing capability at an operating speed of 1000 times/sec There are substantial interfaces that allow direct connection to major PLCs including OMRON DeviceNet and MITSUBISHI CC-Link. F805A, which was developed specifically for weighing systems, is a full-fledged device of an all-in-one type that deserves to be called the top-of-the-line loadcell controller.
- CE Marking Certification
- RoHS-compliant Product
- The weighing indicator suitable for use in any kind of application, either in measuring equipments requiring high level of sequence such as hopper scales and packing scales or in general platform scales having simple applications.
- 5.7 inch color LCD module & LCD touch panel
- Direct PLC Connection
- A wide range of interaces (otional) is availbale for the networking of measuring work throuh its DeviceNet and CC-Link Connections.
- High Speed A/D conversion and powerful digital processing capabilities of 1000 times/sec., for rapid response to input signal.
- High Display Resolution
- 1/10000 at all range is assured.
- Selectable Powerful filter
- Bessel low pass filter for the removal of mechanical vibration, and moving averaging digital filter are pre-istalled.
- Free Power Source
- Caters for AC100V ~ 240V without having to switch over.
- DC power supply can also be specified when making your order.
Touch Panel
English - Japanese language can be selected simply by touching on the touch panel.
Each item is easily set without seeing the operation manual.
Specifications Unipulse F805A
ANALOG SECTION | |
Excitation voltage | 10V or 5V DC±5% (digital adjustment), Output current; within 120mA, remote sense type (Up to 4 loadcells at 350Ω are parallel-connectable.) |
---|---|
Zero adjustment range | 0 - approx. 2mV/V (digital adjustment) |
Gain adjustment range | 0.3 - 2.0mV/V (digital adjustment) |
Min. input sensitivity | 0.3μV/count (at valid 1/4 scale division), 0.075μV/count (at invalid 1/4 scale division) |
Accuracy | Non-linearity: within 0.01%/FS (Typ: 0.005%/FS at room temperature) Zero drift: within 0.1μV/°C RTI (Typ: 0.08μV/°C) Gain drift: within 15 ppm/°C (Typ: 5 ppm/°C) Noise: within 0.1μVp-p RTI (0.1 - 10 Hz) |
Analog filter | Bessel low-pass filter (-12dB / oct.) selectable from 2, 4, 6, 8 Hz |
A/D converter | Speed: 1000 times/sec (switchable to 200 times/sec) Resolution: 16 bit (binary) |
Min. display resolution | 1/10000 (at valid 1/4 scale division), 1/40000 (at invalid 1/4 scale division) |
Secondary calibration | Equivalent input calibration method that allows calibration by simply key-inputting the rated value of a sensor without applying an actual load Min. calibration resolution at secondary calibration (1/1000 at room temperature) |
SETTING SECTION | |
Setting method | ・Setting by touch panel operation ・Setting from host computer via RS-232C is also possible. |
---|---|
Setting value storage | ・Default: NOV RAM (nonvolatile RAM) ・Other setting values: C-MOS RAM with backup of a lithium battery (Depends on usage conditions and storing environment, but memory can be kept for approx. 7 years or more.) |
Setting value protection | Setting operation can be locked to prevent unauthorized modifications of default values and calibration by malfunction (LOCK) |
INPUT / OUPUT SECTION | |
External signal output | - Logic: Transistor’s open collector output (Emitter = COM terminal); Output is LO when transistor is ON. - Near zero, SP1, SP2, SP3, Under, go, over, comp, discharge, Low limit, high limit, stable, weight alarm, error, final error, run or total limit External signal input |
---|---|
External signal input | - Input is ON when shorted to COM terminal by contact (relay switch, etc.) or non contact (transistor, open collector, etc.). - Gross / Net weight change, Digital zero, Tare off, Tare reset, Hold or judge, Feed / discharge change, Accumulation command, Accumulation clear, Start, Stop, Discharge command, Code No. designation, Forced-discharge command, Discharge gate open, Discharge gate close, Code No. designation selection, Graph drawing |
Weighing code selection input | BCD 2 digits (00 - 99), 100 codes |
Interface | ・ SIF:2-wire type serial interface (standard); Interface to link with Unipulse printer or external display ・ SI2:2-wire type bi-directional serial interface (standard): Interface to link with peripherals such as a printer or display ・ 232:RS-232C communication interface (standard): Write (change) / read weight data, various statuses and setting values via commands from host computer ・ BCO:BCD parallel data output interface (Optional): Parallel interface to transmit weight data to various peripherals ・ BCI:BCD parallel data input interface (Optional): Parallel interface to receive various setting values from external unit ・ 485:RS-485 communication interface (Optional): Allows longer-distance communication than RS-232C. ID numbers are set, and multiple units of F805A are parallel-connectable. ・ DAC:D/A converter interface (Optional): Interface to convert weight data to current signal and output it ・ CCL:CC-Link interface (Optional): Interface to link F805A with network such as MITSUBISHI general-purpose sequencer ・ ODN:DeviceNet interface (Optional): Interface to link F805A with DeviceNet such as OMRON CompoBus/D |
DISPLAY SECTION | |
Display | STN color LCD (Display area 117.2 (W) x 88.4 (H) [mm], 320 x 240 dot |
---|---|
Weight value display | 5 digits, Minus sign on most significant digit. |
Unit | Selectable from t, kg, g, N, lb, none |
Decimal point | Selectable 0. 0.0, 0.00, 0.000 |
Display update rate | Selectable from 3, 6, 13, 25 times/sec (A/D conversion rate is fixed.) |
Scale capacity | 5-digit numerical values (up to 99999) |
Over display | LOAD (A/D converter input over), OFL1; (Net weight > Net over set value) [5-digit setting], OFL2: (Gross weight >Capacity +9 scale divisions). OFL3; Gross weight > Gross over set value (5-digit setting) |
Center zero | True zero point (0±1/4 scale) or the center of each value is displayed. |
Status display | LOCK, HOLD, ZALM, STAB, TARE, RUN, HI, LO, NZ, SP1, SP2, SP3, OVER, GO, UNDER, COMPL, DCHG |
Set value display | CODE, FINAL, OVER, UNDER, BEFORE FINAL, FF |
Accumulation display | Accumulation times (4 digits), Accumulation value (9 digits) |
No. display | Alarm No. (2 digits): Error No. in sequence control Sequence No. (3 digits): Process No. in sequence control |
GENERAL SPECIFICATIONS | |
Excitation voltage | 100 - 240V AC (+10% - 15%) (Free power supply 50/60 Hz) 12 - 24V DC (±15%) (Please specify when ordering) |
---|---|
Power consumption | 20W |
Inrush current (Type) | 15A, 5msec: 100V AC average load condition (cold start at room temperature) 30A, 5msec: 200V AC average load condition (cold start at room temperature) 10A, 0.5msec: 12V DC average load condition (cold start at room temperature) 35A, 0.4msec: 24V DC average load condition (cold start at room temperature) |
Operating conditions | Temperature: Operating temperature range 0 - +40°C; Storage temperature range -20 - +60°C Humidity: within 85% RH (no condensing) |
External dimensions | 174 (W) x 135 (H) x 159 (D) mm (protruding part not included) |
Panel cutout dimensions | 165 (W) (+2 - 0) x 130 (D) [mm] |
Panel thickness | 1.6 - 3.2 mm |
Weight | Approx. 2.3 kg |
CE marking receiving | EN61326-1, EN61010-1 (Please specify requirement for CE marking certified product when making your order) (DC power supply is not certificationed to CE Marking. ) |
OPTION | |
BCO | BCD parallel data output interface |
---|---|
BCI | BCD parallel data input interface |
DAC | D/A converter interface (2ch interface installed) |
485 | RS-485 communication interface* |
ODN | DeviceNet interface* |
CCL | CC-Link interface* |
Number of option installations | Up to 4 options and 1 serial communication interface are available. (With*, only 1 option is available.) |
Options
Model | Interface | Slots installed |
BCO | BCD parallel data output interface (General-purpose slot option…3 slots installed (① to ③below)) |
1~3 |
---|---|---|
BCI | BCD parallel data input interface (General-purpose slot option…3 slots installed (① to ③below)) |
1~3 |
DAC | D/A converter interface (General-purpose slot option…3 slots installed (① to ③below)) |
1~3 |
485 | RS-485 communication interface (Advanced communication slot option…1 slot installed (④ below)) |
4 |
ODN | DeviceNet interface (Advanced communication slot option…1 slot installed (④ below)) |
4 |
CCL | CC-Link interface (Advanced communication slot option…1 slot installed (④ below)) |
4 |
CATALOGUE PRODUCT
Untuk informasi lebih lanjut silakan hubungi bagian Marketing kami, kami senang untuk membantu :
Hubungi | : Sales & Marketing |
Alamat |
: Simprug Plaza |
Jl. Simprug Raya Blok B.2 No.5 Cikarang Baru Jababeka II - Bekasi 17530 |
|
Telepon |
: 021 2851 8058 | 021 2851 8059 | 021 3725 0521 | 021 4448 9918 |
Mobile | : 0821 2570 0690 | 0858 9027 2127 | 0877 8228 6338 |
Fax | : 021 2851 8058 |
: scales@kitomaindonesia.com | kitomascale@gmail.com | timbangan@kitomaindonesia.com |